background image

 

10

 
 

Yearly Timer 

 
The yearly timer can be programmed to overtake control of the weekly timer and turn ON or OFF the 
relay on certain days at certain times. 
 
For example; to turn OFF the relay on 1

st

 of September 2019 from 7:00AM till 13:00PM the next day.  

This feature is very useful for setting public holidays and special events without the need of 
accessing the unit on site.  

 
Please Note ! 

This unit will automatically adjust the local time when daylight saving is due.   

 

1.  How to set the Yearly Timer 

:    

The following SMS message is an example of how to set the yearly timer

:

 

 
SMS send:  

9999YT.021219.

0000.

051219.

2400.

OFF

 

 

“9999”       The default password 9999   
“YT”           setting the 

Yearly Timer

   

“021219

”   

starting date is 2

nd

 Dec. 2019  

0000”       

The time that the Yearly Timer will take control over the weekly timer is to be 00:00AM    

“051219

”   

Ending date 5

th

 Dec. 2019  

2400”       

The time when the yearly timer finishes taking control over the weekly timer at 24:00PM    

OFF

”     

   The yearly timer will set the relay to OFF during the above day and interval of time.  

  
The unit will reply by SMS that says:  

 
“Confirming: Yearly Timer OFF: 02.12.19, 00:00AM till 05.12.19, 24:00PM”.      

 

Another example:   

 
SMS send:  

9999YT.050119.

0000.

050119.

2400.

ON

 

 
The unit will reply by SMS that says:  

 
“Confirming: Yearly Timer ON: 05.01.19, 00:00AM till 05.01.19, 24:00PM”.      

  

  

 

 Please Note     

During the interval time when the relay is OFF (not active) the unit will respond to incoming calls of 
the users and will trigger the relay according to the setting. 
 
During the interval time when the relay is ON (active) the unit will not respond to incoming calls of 
the users, but it will send the users that call the unit SMS message saying:  

 
"Your call was disregarded as the TIMER is ON at the moment"

 

 
 
 
 

Summary of Contents for GSM-18V4.1

Page 1: ...s GSM 18V4 1 Access control only GSM 18V4YT Access control with Yearly Timer User Manual Version 1 2019 Manufactured by ECA Electronic Engineering Pty LTD Address 76 80 Levanswell Rd Moorabbin Vic 318...

Page 2: ...d and connect the Antenna before you power up the unit Do not attach the unit s antenna to any metal surface The unit can operate with voltage between 12V to 18V AC or DC using the Black and Red wires...

Page 3: ...by one SMS command The unit should reply by SMS that says Confirming 0417315263 0418655002 added 0902345678 deleted Please Note The unit disregards any phone numbers that were listed and could not be...

Page 4: ...The unit should reply by SMS that says Confirming The number 0418317452 allowed unlimited entries on Sundays Mondays Saturdays between 9 00AM and 5 00PM b The following SMS message is an example of ho...

Page 5: ...fault time setting for the relay is a Pulse of 1 second You can choose and set the PULSE time interval of the relays by SMS as follows 9999pulse_ _ The two under lines _ _ after the word pulse represe...

Page 6: ...t will reply by SMS There are XXXX normal users and XXX special users in the system 11 How to LOCK UNLOCK the system The unit can be LOCKED so that none of users can use the system and activate the re...

Page 7: ...DELETE all the phone numbers and set the unit to factory default To proceed and default the unit you must confirm within 2 minutes by SMS saying YES must be in Capital letters The unit will confirm b...

Page 8: ...when the status input is not connected to ground 18 INPUT 2 ALERT This input can be used to ALERT someone on his mobile phone each time input 2 is triggered This can be used as a DOOR BELL or ALERT th...

Page 9: ...r ON Sunday Monday Saturday between 9 00AM and 17 00PM Please Note When the unit s relay is ON active by the weekly timer the unit will not respond to incoming calls and will not trigger the relay for...

Page 10: ...l take control over the weekly timer is to be 00 00AM 051219 Ending date 5th Dec 2019 2400 The time when the yearly timer finishes taking control over the weekly timer at 24 00PM OFF The yearly timer...

Page 11: ...1 The unit is limited to register up to 50 comments events for the yearly timer 2 Each SMS reply from the unit will include two events only accordingly the report from the Yearly Timer will be sent o...

Reviews: