Chengdu Ebyte Electronic Technology Co.,Ltd.
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
18
Set the
command
AT+CNWKSKEY=<value>
OK
The
description
of the
parameter
<value >: node NwkSKey
Returns the
value
description
example
AT+CNWKSKEY=AABBCCDD00112233AABBCCDD00112233
OK
Precaution
s
ABP when using, setting or reading NwkSKey,returning Y1Y2
...
Y16, 16 feed
format, value 16 bytes.
CFREQBAND
MASK
(Set
the band
mask).
The
command
type
The command format
response
Test
command
AT+CFREQBANDMASK=?
+CFREQBANDMASK:“mask”
OK
Query
command
AT+CFREQBANDMASK?
+CFREQBANDMASK:<mask>
OK
Set the
command
AT+CFREQBANDMASK=<m
ask>
OK
The
description
of the
parameter
< mask >: Frequency point masks that the network may work with, 16bits for 16
frequency groups, see The LoRaWAN access specification.
For example: 0-7 channel, the corresponding mask is 0001, 8-15 channel
corresponding mask is 0002, and so on
Returns the
value
description
example
AT+CFREQBANDMASK=0001
OK
Precaution
s
You need to set it up before Youin.
Command
character
The
command
type
The command format
response
CULDLMODE
(Set
up and
down the
same
frequency).
Test
command
AT+CULDLMODE=?
+CULDLMODE:
“
mode
”
OK
Query
command
AT+CULDLMODE?
+CULDLMODE:<mode>
OK
Set the
command
AT+CULDLMODE=<mode>
OK
The
<mode>
: