example
AT+CNBTRIALS=1,2
OK
Precautions You need to set it up before you can send the data
Command
character
The
command
type
The command format
response
CRM
(Set the
reporting
mode).
Test
command
AT+CRM=?
+CRM:
“
reportMode
”
,
”
reportInterval
”
OK
Query
command
AT+CRM?
+CTXP:<reportMode>,[reportInterval]
OK
Set the
command
AT+CTXP=<reportMode>,[r
eportInterval]
OK
The
description
of the
parameter
<reportMode>:
0- Non-periodic reporting data;
1- Cycle reporting data;
<reportInterval>: This parameter is only available when periodic reporting data.
The time interval between periodic reporting of data, in s.
For different DR, the minimum allowed periods are different, defined by the
periodic level, as shown in the following table.
Rate/cycle (s)/grade LV1 LV2
DR0
150
300
DR1
75
150
DR2
35
70
DR3
15
30
DR4
10
20
DR5
5
10
Returns the
value
description
example
AT+CRM=1,10
OK
Precautions You need to set it up before you can send the data
Command
character
The
command
type
The command format
response
CTXP
(Set
the send
power).
Test
command
AT+CTXP=?
+CTXP:
“
value
”
OK
Query
command
AT+CTXP?
+CTXP:<value>
OK
Set the
command
AT+CTXP=<value>
OK
The
description
<value >: Factory value is 0 for the transmit power size
0 - 17dBm