Ebsray R75 Installation, Operation & Maintenance Instructions Manual Download Page 7

Publication No.: 2753-20 

 

5.5 IMPELLER & MECHANICAL SEAL REPLACEMENT 

The pump should rest on its inlet flange. 

1. 

Remove  the  Cover’s  eight  cap  head  setscrews  (6).  If 
required  fit  two  of  the  setscrews  to  the  tapped  jacking 
holes. 

2. 

Remove  the  Cover  (2),  remove  the  Cover  O-ring  (4), 
discard and replace with lightly lubricated new O-ring. 

NOTE: 

The cover is a very neat fit into the pump body.  Do not use 

excessive force to remove the cover.  If the cover gets stuck, 

gently rock loose or gently tap loose with a soft mallet. 

NOTE: 

The impeller is ‘floating’ on the shaft for most applications 

For certain applications, Ebsray specifies that the Impeller is 

to be locked to the shaft via a socket set screw in the impeller. 

The locked impeller variants are shown with an 

“L” in the 

model number - example 

R80-C33B-1F

L

1-Y1V2R-P0 

 

The following instructions are for a floating Impeller. 

 

Refer to Section 6.2 for removal and replacement of the locked 

Impeller.   

3. 

Remove the Impeller (2) and Impeller Key (8). If required, 
use 2 off M8x75mm setscrews as jacking screws in the 
Impeller’s taped holes. 

4. 

Remove the Circlip (58). At this point you can remove the 
dynamic element by using two of the four cartridge cap 
head setscrews (57A) and fit them to the back of the Seal 
Sleeve (42) (part of the dynamic element (56)) and use 
as  extraction  screws.  If  replacing  the  entire  seal  follow 
steps below. 

5. 

Remove the cartridge cap head setscrews and screw two 
of them into 

the Mechanical Seal Cartridge’s (57) tapped 

jacking holes. Jack the Cartridge and/or Mechanical Seal 
Assembly (56) off the shaft. 

6. 

Remove  the  dynamic  element  (41,  42,  45,  45A,  46 
assembled)  and  Seal  Seat  (40)  from  the  Cartridge. 
Remove  the  O-rings  (57B  &  C)  from  the  Cartridge  and 
discard. 

7. 

Fit  a  small  screwdriver  or  punch  to 
the Cartridge’s holes and gently tap 
the Lip Seal (55) out (See Figure 4). 

8. 

Clean  the  Cartridge  using  non-
residual contact cleaner or similar. 

9. 

Loosely  fit  the  new  Lip  Seal  to  the 
Cartridge  (with  the  lip  facing  out, 
See Figure 5). Using the piece of 1-
1/4 inch pipe as a drift, gently tap the 
Lip  Seal  into  the  Cartridge.  Ensure 
that  the  Lip  Seal  is  flat  (flush)  by 
checking the holes in the back of the 
Cartridge. 

10. 

Fit  the  smallest  new  O-ring  (48)  to 
the Seal Seat and lightly lubricate. 

11. 

Without  removing  the  protective  cover,  press  the  Seal 
Seat into the Cartridge with fingers (ensuring complete 
and square engagement). 

12. 

Remove the protective cover from the Seal Seat, clean 
with non-residue contact cleaner. 
 

13. 

Fit the new O-rings (57B & 57C) to the Cartridge and 
lightly lubricate. The smaller cross section O-ring goes 
on the back. 

14. 

Lightly lubricate the Cartridge O-rings, Lip Seal and bore 
of the Bearing Housing (20). 

15. 

Aligning the four holes of the Cartridge with the tapped 
holes in Bearing Housing, fit the Cartridge to the 
Bearing Housing. 

16. 

Fit the four Cartridge cap head setscrews with ‘Loctite 
243’ or similar and tighten to 7N-m (5ft-lbs). 

17. 

Remove the protective cover from the dynamic 
element and clean face with non-residual contact 
cleaner. Lightly lubricate the new internal Shaft O-ring 
(46) and lubricate seal face with clean light machine 
oil. 

 
18. 

Aligning the dynamic element pin 
with the Impeller

’s keyway, fit the 

dynamic element onto the shaft 
and rest gently on the Seal Seat’s 
face. 

19. 

Loosely  fit  the  Circlip  (58)  onto  the 
shaft. Using the 1-1/4 inch pipe as a 
press  tool,  snap  the  circlip  into 
place. Ensure the Circlip is correctly 
seated (See Figure 6). 

 

20. 

Fit the new Impeller Key (8) to the keyway. Aligning the 
Impeller keyway to the shaft key, fit the Impeller to the 
shaft. 
 

NOTE: 

Correct angular orientation of both the cover and bearing 

housing is guaranteed as one of the bolt holes is 1.5 degrees 

out of pitch. In other words if all eight bolts do not start in the 

Body’s tapped holes the angular orientation is not correct. 

 

21. 

Gently fit the Cover (2) to the Body (1). 
Do not force the cover into the body.  
If  it  gets  stuck,  gently  rock  loose  or 
gently tap it in with a soft mallet. 

22. 

Do a final check to ensure the Cover 
O-ring  (4)  is  correctly  located  (See 
Figure 8), then hand fit the eight cover 
cap  head  setscrews  (6).  Torque 
setscrews to 100Nm (75 ft-lb

’s) 

Figure 4 

Figure 5 

Figure 8 

Summary of Contents for R75

Page 1: ...damage Warns of hazards that WILL cause serious personal injury death or major property damage Warns of hazards that CAN cause serious personal injury death or major property damage Warns of hazards...

Page 2: ...formation pertaining to the pump is required this data must be furnished to an Ebsray representative Some pump models are listed by Underwriters Laboratories for LP Gas and or Anhydrous Ammonia servic...

Page 3: ...e incurred during transit should be noted on the packing note and on both your own and the carrier s copy of the consignment note Should a shortage be evident on receipt notify Ebsray immediately givi...

Page 4: ...ters provide straight alignment of the motor drive through a coupling connected to a straight key pump shaft 3 9 LONG COUPLED AND BELT DRIVES The R80 and R82 pumps are also designed to be long coupled...

Page 5: ...such conditions as excessive heating of ball bearings vibration or unusual noises NOTE Consult SECTION 9 of this manual if difficulties during start up are experienced and troubleshooting is required...

Page 6: ...ump must be fully flushed out i e returned in the state it was provided Numbers in parentheses i e Cover 2 following individual parts indicate reference numbers specified in SECTION 7 and 8 Steps befo...

Page 7: ...ing the piece of 1 1 4 inch pipe as a drift gently tap the Lip Seal into the Cartridge Ensure that the Lip Seal is flat flush by checking the holes in the back of the Cartridge 10 Fit the smallest new...

Page 8: ...ort the Impeller side of the DEB s inner raceway and press the driven end of the Shaft until the DEB is pushed off the Shaft 2 Then support the driven side of the IEB and press from the Impeller end o...

Page 9: ...eight bearing housing cap head setscrews and torque to 100 Nm 75 ft lbs 13 Aligning the Impeller keyway to the shaft key fit the Impeller to the shaft 14 Fit the Cover to Body note that the raised ca...

Page 10: ...Head Setscrew 8 101 Adaptor Flange Elbow 1 33 Dust Seal Bearing 1 101A Adaptor Flange Elbow Plug 1 34 Key Driver 1 102 Blanking Flange 1 40 Seal Seat 1 103 Valve Cover 1 41 Seal Face 1 103A O ring Val...

Page 11: ...Publication No 2753 20 11...

Page 12: ...1 20 Bearing Housing 1 99 Bearing Cap 1 21 Shaft 1 99A O ring Bearing Cap 1 23 Ball Bearing Inspection end 1 99B Cap Head Setscrews 8 24 Ball Bearing Drive end 1 100B Cap Head Setscrews 8 25 Circlip B...

Page 13: ...Publication No 2753 20 13...

Page 14: ...ture or Speed not as per design conditions Foreign matter jamming parts Pump out of alignment with driver Parts worn End of service life or adverse pumping conditions Excessive Noise Foreign matter ja...