Ebsray R75 Installation, Operation & Maintenance Instructions Manual Download Page 2

Publication No.: 2753-20 

 

 

It is the responsibility of the designer, fabricator and the installer 
of each required sub-system to ensure that: 

 

a) 

The Ebsray specifications within this publication and any 

other  relevant  Ebsray  documents  are 

STRICTLY

 

adhered to. 

b) 

Any  variation  (including  the  use  of  equipment deemed 

"Equivalent")  or  addition  to  Ebsray  specifications,  as 
related to the pumpset and pumping system in general, 
meet Ebsray's minimum requirements. 

c) 

All  design,  fabrication  and  installation  of  the  tank  and 

sub-systems  is 

STRICTLY

  in  accordance  with  all 

relevant  National,  State  and  Local  Directives, 
Standards, Codes and Regulations. 

d) 

All equipment is suitable for the hazardous area as defined 
by EN6079.10.1 

e) 

All 

Essential Health and Safety Requirements (EHSR’s) as 

outlined in EN60079.14, EN15198, EN ISO 80079-36 and 
EN ISO 80079-37 are adhered to. 

f) 

All relevant requirements of NFPA 58 for UL Listed Models. 

 

This product is CE marked (meaning the equipment has been 
assessed and supplied in conformity to those Directives), strict 
adherence with all instructions and recommendations forms an 
essential part in maintaining the product/equipment’s conformity. 
Failure to comply with the instructions and recommendations 
contained in this Publication may void CE conformity. 

 

 
 

SECTION 2 - PUMP DATA

2.1 

PUMP IDENTIFICATION 

A pump identification tag, containing the pump serial 
number, I.D. number, and model designation, is attached to 
each pump.  It is recommended that the data from this tag 
be recorded in SECTION 2.3. If replacement parts are 
needed, or if information pertaining to the pump is required, 
this data must be furnished to an Ebsray representative. 
 
Some pump models are 

listed by Underwriters’ Laboratories 

for LP Gas and/or Anhydrous Ammonia service. 
 

2.2 

TECHNICAL DATA 

Minimum/Maximum 
Operating Temperature 

-40

O

C (-40

O

F)/ 

135°C (275°F) 

Maximum Pump Speed 

3500 RPM 

Maximum Differential 
Pressure 

1400 kPa (14 Bar) 

Maximum Working 
Pressure for non-UL Listed 

2920 kPa  (29.2 Bar) 

Maximum Working 
Pressure for UL Listed 

2760 kPa (27.6 Bar) 

Technical Data is for standard materials of construction.  
Consult Ebsray Material Specs for optional materials of 
construction. 

 

2.3 

INITIAL PUMP START UP INFORMATION 

Model No. 

 
 

Serial No. 

 
 

Equipment No. 
 

 

Date of 
Installation 

 

Inlet Gauge 
Reading 

 

Discharge 
Gauge Reading 

 

Flow Rate 

 
 

 

 

Failure to set the vehicle emergency 

brake and chock wheels before 
performing service can cause severe 
personal injury or property damage 

 

 

Failure to relieve system pressure prior 
to performing pump service can cause 
serious personal injury or property 
damage.

  

Systems with meters will still be 

pressurized even after the hose is 
emptied

 

 

 

 

Hazardous 

machinery can 

cause serious 

personal injury.

 

 

Hazardous pressure 

can cause serious 

personal injury or 

property damage 

 

 

 

 

 

 

Failure to disconnect and lockout 

electrical power or engine drive before 
attempting maintenance can cause 
severe personal injury or death 

 

 

Operation without guards in place can 
cause serious personal injury, major 
property damage, or death. 

 

 

 

Hazardous 

machinery can 

cause serious 

personal injury.

 

 

Do not operate 

without guard  

in place

 

 

 

 

 

 

 

Disconnecting fluid or pressure 
containment components during pump 
operation can cause serious personal 
injury or property damage.

 

 

 

 

 

 

 

Hazardous pressure 

can cause serious 

personal injury or 

property damage 

 

 

 

 

 

 

 

Summary of Contents for R75

Page 1: ...damage Warns of hazards that WILL cause serious personal injury death or major property damage Warns of hazards that CAN cause serious personal injury death or major property damage Warns of hazards...

Page 2: ...formation pertaining to the pump is required this data must be furnished to an Ebsray representative Some pump models are listed by Underwriters Laboratories for LP Gas and or Anhydrous Ammonia servic...

Page 3: ...e incurred during transit should be noted on the packing note and on both your own and the carrier s copy of the consignment note Should a shortage be evident on receipt notify Ebsray immediately givi...

Page 4: ...ters provide straight alignment of the motor drive through a coupling connected to a straight key pump shaft 3 9 LONG COUPLED AND BELT DRIVES The R80 and R82 pumps are also designed to be long coupled...

Page 5: ...such conditions as excessive heating of ball bearings vibration or unusual noises NOTE Consult SECTION 9 of this manual if difficulties during start up are experienced and troubleshooting is required...

Page 6: ...ump must be fully flushed out i e returned in the state it was provided Numbers in parentheses i e Cover 2 following individual parts indicate reference numbers specified in SECTION 7 and 8 Steps befo...

Page 7: ...ing the piece of 1 1 4 inch pipe as a drift gently tap the Lip Seal into the Cartridge Ensure that the Lip Seal is flat flush by checking the holes in the back of the Cartridge 10 Fit the smallest new...

Page 8: ...ort the Impeller side of the DEB s inner raceway and press the driven end of the Shaft until the DEB is pushed off the Shaft 2 Then support the driven side of the IEB and press from the Impeller end o...

Page 9: ...eight bearing housing cap head setscrews and torque to 100 Nm 75 ft lbs 13 Aligning the Impeller keyway to the shaft key fit the Impeller to the shaft 14 Fit the Cover to Body note that the raised ca...

Page 10: ...Head Setscrew 8 101 Adaptor Flange Elbow 1 33 Dust Seal Bearing 1 101A Adaptor Flange Elbow Plug 1 34 Key Driver 1 102 Blanking Flange 1 40 Seal Seat 1 103 Valve Cover 1 41 Seal Face 1 103A O ring Val...

Page 11: ...Publication No 2753 20 11...

Page 12: ...1 20 Bearing Housing 1 99 Bearing Cap 1 21 Shaft 1 99A O ring Bearing Cap 1 23 Ball Bearing Inspection end 1 99B Cap Head Setscrews 8 24 Ball Bearing Drive end 1 100B Cap Head Setscrews 8 25 Circlip B...

Page 13: ...Publication No 2753 20 13...

Page 14: ...ture or Speed not as per design conditions Foreign matter jamming parts Pump out of alignment with driver Parts worn End of service life or adverse pumping conditions Excessive Noise Foreign matter ja...