LX20B – Manual
Page 37 / 67
Defines conditions for activating both of outputs. User can set following conditions:
o
No connection to server (immediately after detection);
o
No GSM signal (immediately after detection);
o
Detection of incoming call from defined telephone number;
After selecting this option can be generated CLIP event, if appropriate
position in the “Monitoring” group is set (see item 7.4.5.). You can enter full
phone number or only a part of number. The device will detect all numbers
with specified sequence. E.g. if entered number is
1234
, the output will
activate after incoming call from number
1234
56789 or 600
1234
56.
Note: The phone number must me entered without country code (e.g.
without prefix 0048 and +48).
o
Dependent on state transitions from non-active to active of one of the inputs.
Outputs can be also activated by internal watchdog, which can be configured in
“Link control” group (see chapter 7.7.).
7.3.3.3.
Additional conditions
If option “Dependent on state transitions from non-active to active of one of the
inputs” is chosen, we might configure additional conditions for output activations:
o
Never:
input disturbance does not cause operation of sabotage output,
o
No network:
input disturbance causes actuation of sabotage output if
sending of information to server is impossible.
o
Always:
every input disturbance causes actuation of sabotage output.
o
Available network:
input disturbance causes actuation of sabotage output
if
sending of information to server is possible.
Note:
Both outputs may be controlled by SMS commands.
7.3.4.
Advanced outputs control
The user is able to determine an alternative course of action to go over basic
outputs configuration function described in section
7.3.3. Outputs
. In the “Advanced
outputs control” you may define separately the behavior of each of the outputs,
depending on events taking place. “Advanced outputs control” differs from the
existing basic “Outputs configuration” by:
o
it is possible not only to turn on but also to turn off the output
o
output can be activated temporarily for specified amount of time
o
there is a complete list of events for which you can define the behavior of the
output
Note: Do not use at the same time the basic configuration of outputs (
7.3.3.
Outputs
) and the “Advanced outputs control”!
In particular, the basic configuration of existing options: “No GSM signal
(immediately after detection)” and “Dependent on state transitions from non-active
to active of one of the inputs” should not be used with their replacements “[Off]
GSM” and “[On] Input x”. The use the basic configuration of outputs and “Advanced
outputs control” at the same time, may cause unexpected behavior of the
transmitter.