![EBS LX20B Installation And Programming Manual Download Page 62](http://html1.mh-extra.com/html/ebs/lx20b/lx20b_installation-and-programming-manual_3830363062.webp)
LX20B – Manual
Page 62 / 67
SIMTEST
(only for LX20B-5D model)
The command is used to switch into the inactive SIM
card in the device and test its.
GETPARAM=parameter_name Gets inquired parameter :SERVER, PORT, APN, UN,
PW, DNS1, DNS2, SMS, SMSPERIOD
GETCFG
Gets primary communication parameters of device in
form: SERVER:PORT,APN UN PW,DNS1
APN=apn
Access point to GPRS network via SIM 1 cards.
Parameter should be obtained from mobile network
operator. If APN address contain space sign put it
with “”, e.g. “my apn”.
APN2=apn
(only for LX20B-5D model)
Access point to GPRS network via SIM 2 cards.
Parameter should be obtained from mobile network
operator. If APN address contain space sign put it
with “”, e.g. “my apn”.
UN=un
APN user name for SIM 1 card. Parameter should be
obtained from mobile network operator. If APN user
name contain space sign put it with “”, e.g. “my user
name”.
UN2=un
(only for LX20B-5D model)
APN user name for SIM 2 card. Parameter should be
obtained from mobile network operator. If APN user
name contain space sign put it with “”, e.g. “my user
name”.
PW=pw
APN password for SIM 1 card. Parameter should be
obtained from mobile network operator. If APN
password contain space sign put it with “”, e.g. “my
password”.
PW2=pw
(only for LX20B-5D model)
APN password for SIM 2 card. Parameter should be
obtained from mobile network operator. If APN
password contain space sign put it with “”, e.g. “my
password”.
SERVER=server
Primary server address; it can be in form of IP or
domain name address.
SERVER2=server
(only for LX20B-5D model)
Secondary server address; it can be in form of IP or
domain name address.
PORT=port
Primary server port number.
PORT2=port
(only for LX20B-5D model)
Secondary server port number.
SMS=phone_number
Server phone number. When there is GPRS failure,
SMS with events will be sent to this number.
SMSPERIOD=time
Defines in minutes time between SMS test messages
sending to the server.
RLIMIT
Removes automatic temporary locks on all inputs
RLIMIT=inputs_mask
Removes selected automatic temporary locks.
Parameter is decimal number made from 6-bit word:
A5, A4, A3, A2, A1, A0; where A1 means INPUT 1, A2
– INPUT 2, A3 – INPUT 3, A4 – INPUT 4, A5 – INPUT
5, A0 is not used.
EXAMPLE:
RLIMIT=6
– removes locks on inputs: IN1, IN2
RLIMIT=2
– removes lock on input IN1
DT=YY/MM/DD,hh:mm:ss
Set time in the transmitter. Time must be specified in
a format compatible with the field on the left.
FLUSH=x
Flushes events buffer, where
x
:
2 – system events history
Summary of Contents for LX20B