42
RIO
PL
www.eberg.eu
7. TROUBLESHOOTING
SYMPTOM
INSPECTION
SOLUTION – CORRECTIVE ACTION
The unit is not
operating
Check the power connectionin
securely.
Insert the power cord securely into the
wall outlet.
Check if the water level indicator lights
up?
Empty the drain pan by remove the
rubber plug.
Check the room temperature.
The range of operating temperature is
5-35 °C.
The unit works with
reduced capacity
Check the air filter for dirt.
Clean the air filter as necessary.
Check if the air duct is blocked.
Remove the obstacle.
Check if the room door or window is
open.
Keep the door and windows closed.
Check if the desired operating mode
is selected and the temperature is
properly set.
USet the mode and temperature at
proper set-point according the manual.
(refer to page69)
The exhaust hose is detached.
Make sure the exhaust hose is securely
attached.
Water Leakage
Overflow while moving the unit.
Empty the water tank before transport.
Check if the drain hose is kinked or
bends.
Straighten the hose to avoid a trap
existing.
Check if the unit is securely positioned. Place the unit on horizontal and firm
ground.
Check if any loose, vibrating parts.
Secure and tight the parts.
Noise sounds like water flowing.
Noise comes from flowing refrigerant.
This is normal.
Error Codes
ground level.
2. Eliminate every possible source of ignition.
3. Use appropriate personal protection equipment (PPE).
4. Evacuate unnecessary personnel, isolate, and ventilate area.
5. Do not get in eyes, on skin, or on clothing. Do not breathe vapors or gas.
6. Prevent entry to sewers and public waters.
7. Stop the source of the release, if safe to do so. Consider the use of water spray to disperse
vapors.
8. Isolate the area until gas has dispersed. Ventilate and gas test area before entering. Contact
competent authorities after a spill.