EPD 50 | EPD 70
EN
34
www.eberg.eu
1. Switch off the unit and remove air filter
2. Rinse the air filter under running water.
Warning!
Do not touch the evaporator surface with bare-hand, or could cause injury of your fingers.
Please read the following points before cleaning refrigeration systems.
1. R290 is heavier than air. May accumulate in confined spaces, particularly at or below ground level.
2. Eliminate every possible source of ignition.
3. Use appropriate personal protection equipment.
4. If refrigerant is released, evacuate personnel, isolate, and ventilate area.
5. Do not get in eyes, on skin, or on clothing. Do not breathe vapors or gas.
6. Prevent entry to sewers and public waters.
7. Isolate the area until gas has dispersed. Ventilate the room throughly before entering it.
7. TECHNICAL SPECIFICATION
• Dehumidify capacity model EPD 50 (30
O
C, RH 80%): 50l /24h
• Dehumidify capacity model EPD 70 (30
O
C, RH 80%): 70l /24h
• Water tank capacity: 5,5 l
• Rated voltage: 220-240 V
• Rated frequency: 50 Hz
• Refrigerant: R290