5.2. Settings
1. Operation mode
A. Continuous Operation
• Press POWER key to turn on the unit.
• The unit starts to dehumidify in continuous operation, regardless of the humidity. The humidity set-po-
int cannot be adjusted in this mode.
B. Normal Operation
• Press POWER key to turn on the unit.
• Press the CONT key to deactivate the continuous mode. The unit operates in normal mode with the
default 50% humidity set-point.
• Press POWER key again to turn off the dehumidifier. The fan keeps running for a while and then stops.
2.Set Humidity (setting range: 20%-90%):
• The humidity set-point can be adjusted in normal operation.
• Press ADD/MINUS key repeatedly to adjust humidity set-point, pressing one of the button will change
the value by 5%.
• Set the humidity level between 40% and 60% for comfort.
• The unit will cycle on and off to maintain the level.
3.Timer Setting (1hour-24hours):
a) The timer has two ways of operation:
To turn off (When power on)
Press Timer key to turn on the timer function. Press ADD/MINUS repeatedly to set the delay OFF time.
To turn on (When power off)
Press Timer key to turn on the timer function. Press ADD/MINUS repeatedly to set the delay ON time.
Cancel timer
When press POWER will exit the timer setting.
4. Water FULL Indicator
The machine automatically shuts off once the water tank is full, alerting the user through an indicator
light and buzzing.
If the water tank is full, empty and re-install the water tank.
If the water tank is not in position, the full indicator always on and the unit is inoperative. Re-install the
tank correctly, and the unit will auto operating as your last setting.
5. Room Temperature Inspection
In addition to the humidity level, the digital display can also indicate the current room temperature.
Please check as follows:
• Press and hold the TIMER button for 5 seconds. The screen displays the temperature in degree Celsius.
6. Automatic Defrost function
At low room temperatures, frost may buildup at the evaporator reducing the airflow across it during
dehumidifying.
• The dehumidifier will automatically start defrosting.
• The Defrost LED blinking.
• The compressor stops and the fan keeps running.
• Do not turn off the unit and it will automatically restart dehumidifying.