AZARI
EN
20
www.eberg.eu
5. OPERATION
5.1. 3-colors indicator light
Ambient humidity < 45%, the indicator light will show Blue
45% ≤ ambient humidity ≤ 65%, the indicator light will show Green
ambient humidity > 65%, the indicator light will show Red
5.2. Control panel
5.3. Settings
Stand By Button
In the standby state, press the power button to turn on, the operation indicator lights up and
the default fan speed is high, the LED shows ambient humidity. In the power-on state, press the power
button to turn off, the running indicator light goes off and the compressor stops immediately, and then
the fan shut down after 30 seconds delay.
Mode button
Press the mode button to switch between Auto and Continuously dehumidify mode.
Auto mode - continuously dehumidify mode cycle, press once to switch the mode from one to another,
the corresponding indicator will light up.
Auto mode
When the room humidity is 3 percentage points or more above the desired user-set humidity level, the
fan will start immediately, the compressor will start running after 3 seconds.
When the room humidity is 3 percentage points or more below the desired user-set humidity level, the
compressor will stop running and the fan will turn off after a delay.
Both fan speed and humidity setting can be adjusted under Auto mode.
Continuously dehumidify mode
The dehumidification function is permanently activated, the fan runs in high speed.
Both fan speed and humidity can’t be adjusted under continuously drying mode.
Sleep/Reset button
Sleeping mode
Touch the sleep button, the sleep indicator will light up, the mode indicator will go out, and the wind