Note!
The power cord and control wire can’t be crossed or winding.
The drain hose should be bound at the bottom.
STEP 9: HANG THE INDOOR UNIT
1.
Put the bound pipes in the wall pipe and then make them pass through the wall hole.
2.
Hang the indoor unit on the wall-mounting frame.
3.
Stuff the gap between pipes and wall hole with sealing gum.
4.
Fix the wall pipe.
5.
Check if the indoor unit is installed firmly and closed to the wall.
Note!
•
Do not bend the drain hose too excessively in order to prevent blocking.
•
The through-wall height of drain hose shouldn’t be higher than the outlet pipe hole of indoor unit.
•
The water outlet can’t be placed in water in order to drain smoothly.