AORI
EN
39
www.eberg.eu
The Refrigerant
To realize the function of the air conditioner unit, a special refrigerant circulates in the system. The used
refrigerant is the fluoride R32, which is specially cleaned. The refrigerant is flammable and inodorous.
Furthermore, it can leads to explosion under certain condition. But the flammability of the refrigerant is very
low. It can be ignited only by fire.
Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm to the ozonosphere. The
influence upon the greenhouse effect is also lower. R32 has got very good thermodynamic features which
lead to a really high energy efficiency. The units therefore need a less filling.
WARNING:
•
Do not use means to accelerate the defrosting process or to clean, other than those recommended by
the manufacture. Should repair be necessary, contact your nearest authorized Service Center.
•
Any repairs carried out by unqualified personnel may be dangerous.
•
The appliance shall be stored in a room without continuously operating ignition sources. (For example:
open flames, an operating gas appliance or an operating electric heater.)
•
Do not pierce or burn.
•
Appliance filled with flammable gas R32. For repairs,strictly follow manufacturer’s instructions only.
•
Be aware that refrigerants not contain odour.
•
Read specialist’s manual.
OPERATION AND MAINTENANCE
•
This appliance can be used by children aged of 8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe way and understand the hazards involved.
•
Children shall not play with the appliance.
•
Cleaning and user maintenance shall not be made by children without supervision.
•
Do not connect air conditioner to multi-purpose socket. Otherwise, it may cause fire hazard.
•
Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause electric shock.
•
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
•
Do not wash the air conditioner with water to avoid electric shock.
•
After removing the filter, do not touch fins to avoid injury.
•
Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard.
•
Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury or
damage.
•
Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer
when you need to repair air conditioner.
•
Do not extend fingers or objects into air inlet or air outlet. It may cause personal injury or damage.
•
Do not block air outlet or air inlet. It may cause malfunction.
•
Do not spill water on the remote controller, otherwise the remote controller may be broken.
•
When below phenomenon occurs, please turn off air conditioner and disconnect power immediately,
and then contact the dealer or qualified professionals for service.
•
Power cord is overheating or damaged.
•
There’s abnormal sound during operation.
•
Circuit break trips off frequently.
Summary of Contents for AORI E25-09
Page 69: ...eberg eu KARTA GWARANCYJNA URZA DZEŃ KLIMATYZACYJNYCH MARKI EBERG ...
Page 74: ...Data przeglądu Pieczęć i podpis serwisu Uwagi adnotacje Przeglądy techniczne ...
Page 75: ...Data naprawy Opis Pieczęć i podpis Punktu Serwisowego Naprawy ...
Page 76: ...Climateo Sp z o o Kokotów 703 32 002 Kokotów biuro eberg eu tel 48 513 677 545 www eberg eu ...