9. ELECTRICAL CONNECTION

−   ELECTRICAL CONNECTION MUST BE CARRIED OUT BY A QUALIFIED 

ENGINEER.

−   IT  IS  ADVISABLE  TO  INSTALL  A  HIGH  INTENSITY  DIFFERENTIAL 

SWITCH (0.03 A) ON BOTH THE THREEPHASE AND SINGLE PHASE 

VERSIONS.

WARNING!

Motor-driven pumps not equipped with a plug must be 

powered by connecting them permanently to the electri-

cal cabinet equipped with a switch, fuses and thermal 

cut-out calibrated to the pump’s absorbed current.
The mains must be reliably earthed, according to the 

electrical regulations in force in the user’s country: this 

is the installer’s responsibility.
If the motor-driven pump is supplied without a power 

cable, use a cable that complies with the regulations in 

force and the necessary section according to length, 

power and mains voltage.
If present, the plug of the single phase version must be 

connected to the mains far from sprays, water jets or 

rain and it must be accessible.
The three phase version does not have an internal motor 

protector, therefore overload protection must be provi-

ded by the user. From 1.5 kW to 11 kW, the engine is 

equipped with a PTC suitably connected to an electronic 

card.

WHILE CONNECTING, MAKE SURE THAT BOTH THE TERMINAL BOARD AND 

THE MOTOR DO NOT GET WET.

–   Connection of the single phase versions must be made on the basis of 

whether thermoamperometric protection “P” is internal or external.

–   For threephase versions, after connecting the star or triangle cable to 

the terminal board, looking at the pump from the motor side, check that 

the cooling fan turns in the same way as the arrow on the label applied 

on the fan cover. If it is incorrect, swap two of the three wires over on the 

motor’s terminal strip.

MOTOR-DRIVEN EVM series

Before starting to make electrical connections, make sure that line voltage 

and frequency match the motor’s values given on the rating plate.

You  must  insert  a  control  panel  between  the  line  and  the  motor-driven 

pump featuring the following devices (unless otherwise specified by local 

standards); 

-  Switch with at least a 3mm gap between contacts;

-   Short-circuit protection device (fuse or thermomagnetic circuit break

-

er);

-  High-sensitivity (0.03 A) residual current circuit breaker;

-   We recommend installing a device to protect against dry running, which 

must be connected to a float, sensors or other such equipment;

Connect the protective conductor to the PE terminal first, leaving it longer 

than the others so that it will be the last wire to be pulled out if accidentally 

tugged.

If the terminal box is in an awkward position for connecting the cable, you 

can change its position by turning the motor 90° or 180° or 270°. To do 

this, you will need to remove the 4 screws fastening the motor to the sleeve, 

lift the motor just enough to allow rotation, without removing the coupling 

between the motor shaft and pump shaft. Then screw the 4 screws back in.

10. FILLING THE PUMP

WARNING!

Do not start the pump until it has been positioned and 

installed in its final place of operation to be performed 

with the motor’s terminal strip fully closed

The pump and suction line must be filled with water. As specified earlier, 

running  the  pump  without  water  inevitably  causes  serious  damage  to  a 

number of the pump’s internal parts.

Fill the pump with the terminal box closed and the power supply discon

-

nected.

10.1. FILLING PUMP IN SUCTION LIFT ARRANGEMENT

a)   Unscrew the hexagonal cap located above the outer jacket on a level 

with the upper mount (remove coupling covers if necessary);

b)   With the aid of a funnel, fill the suction line and pump casing with water 

to overflowing;

c)   Screw the hexagonal cap back on until it is locked tight;

d)   Areas that have become wet as a result of water leaks must be dried 

thoroughly;

e)  Refit the coupling covers if they have been removed;

10.2  FILLING PUMP IN A FLOODED INSTALLATION

 

a)  Unscrew the hexagonal cap;

b)  Open the suction gate valve until the water comes out;

c)   Screw the cap back on until it is locked tight. Starting and operation;

11. USE, STARTING AND RUNNING

NEVER ALLOW THE MOTOR-DRIVEN PUMP TO OPERATE WITHOUT WA

-

TER. DOING SO CAN SERIOUSLY DAMAGE THE INTERNAL COMPONENTS.

 

11.1. GENERAL WARNINGS

a)   Our surface pumps are designed to operate at a temperature no higher 

than 40°C and a level no higher than 1000 metres;

b)   our motor-driven pumps cannot be used in swimming pools or similar 

plants;

c)   prolonged  motor  pump  operation  with  the  delivery  pipe  closed  can 

cause damage;

d)   avoid switching the motor pump on and off too frequently (check the 

maximum number in Chap. 7.2);

e)   during power cuts, it is advisable to disconnect the power to the pump.

11.2 STARTING

Once the unit has been hooked up electrically and to the water circuit and 

charged with water, check its direction of rotation before using it. 

a)  Start the electric pump with the delivery valve closed. 

b)  Check that the motor rotates clockwise (starting from the fan end - the 

direction  is  also  marked  by  an  arrow  on  the  top  mount)  by  looking 

through the slots in the fan cover. This is best seen when starting or 

stopping the motor. 

c)  If it is rotating in the wrong direction (counterclockwise), shut off power 

and swap two of the motor’s power phases in the electrical enclosure 

or terminal block. 

d)   Start the pump two or three times to check system conditions;

e)   restrict the delivery to cause a rapid pressure increase for a few times;

f)  make sure that the noise, vibration, pressure and electrical voltage lev

-

els are normal.

g)  while driving loosen the vent cap until the water comes out; screw the 

cap back on until it is locked tight.

11.3. RUNNING

Start the pump with the isolating valve on the delivery line closed, then 

open it gradually. The pump must operate smoothly and quietly. Close the 

isolating valve again and make sure that the reading on the delivery line’s 

pressure gauge is close to the Hmax value as indicated on the rating plate. 

(This approximation is mainly attributable to tolerances and to possible suc

-

tion lift). If the pressure gauge reading is much lower than Hmax, repeat 

filling (air in pump).

If the two values are close, it means the pump is working properly and any 

trouble with the isolating valve open is almost always a result of motor sys

-

tem problems of an electrical or mechanical nature or, much more com

-

monly, of pump cavitation due to:

–   excessive difference in height or excessive pressure loss along suction 

line,

–  delivery line backpressure too low;

–   problems associated with liquid temperature.

[-B-]

[-C-]

[-C-]

Summary of Contents for EVM Series

Page 1: ...ating and maintenance manual 12 EVM series TRADUCTION DES INSTRUCTIONS D ORIGINE Manuel d utilisation et d entretien 22 EVM Serie BERSETZUNG DER ORIGINALANLEITUNG Bedienungsanleitung 32 EVM series TRA...

Page 2: ...ZIA E ASSISTENZA TECNICA L INOSSERVANZA DELLE INDICAZIONI FORNITE IN QUESTO LIBRETTO ISTRUZIONI E O L EVENTUALE INTERVENTO SUL PRODOTTO NON EFFET TUATO DAI NOSTRI CENTRI ASSISTENZA INVALIDERANNO LA GA...

Page 3: ...issato al mo tore e non riesca a rovesciarsi o a cadere Movimentazione della sola Pompa seguire la medesima procedura della elettropompa con la sola differenza che la cinghia andr allacciata sul suppo...

Page 4: ...dice articolo 11 N Codice materiali 12 MEI Indice che misura la qualit della pompa rispetto la sua efficienza 13 Hyd Eff Efficienza idraulica della pompa 7 4 INFORMAZIONI SUL RUMORE AEREO Potenza Kw G...

Page 5: ...alle tubazioni a Utilizzare tubazioni metalliche per evitare che possano cedere sotto la depressione che si crea in aspirazione o in materiale plastico con un certo grado di rigidezza b supportare ed...

Page 6: ...L G 10 N 40 M12 2 50 EVMS L G 10 F 40 M16 4 70 EVMS L G 10 LF 40 M16 4 70 EVMS L G 15 N 50 M12 2 50 EVMS L G 15 F 50 M16 4 70 EVMS L G 15 LF 50 M16 4 70 EVMS L G 20 N 50 M12 2 50 EVMS L G 20 F 50 M16...

Page 7: ...Se la scatola morsettiera in una posizione scomoda per il collegamen to del cavo possibile cambiare il suo posizionamento facendo ruotare il motore di 90 o 180 o 270 Per farlo occorre rimuovere le 4...

Page 8: ...condizioni operative prestando attenzione all insorgere di rumorosit e vi brazioni anomale Detti controlli possono dare un indicazione approssimata sull esigenza di interventi di manutenzione straord...

Page 9: ...motore anche ru moroso MANIFESTAZIONE DEL GUASTO CAUSA RIMEDIO LA POMPA SI FERMA DOPO BREVI FUNZIO NAMENTI intervento della protezione termica Temperatura liquido troppo alta La temperatura oltre pass...

Page 10: ...EVM series dotate di parti idrauliche interne in acciaio inossidabile soffrono meno di altre eseguite con materiali meno pregiati per non possono comunque sottrarsi ai danni che la cavitazione comport...

Page 11: ...TTROPOMPE FIG 1 FIG 2 FIG 1 a Buona immersione b Pendenza positiva c Curva ad ampio raggio d Tubazioni con supporti indipendenti e Diamertro tubo aspirazione diametro bocca della pompa f Riduzione ecc...

Page 12: ...ffice Via Campo Sportivo 30 38023 Cles TN ITALIA Telefono 0463 660411 Telefax 0463 422782 2 2 See NAMEPLATE chapter 7 3 3 GUARANTEE AND TECHNICAL ASSISTANCE FAILURE TO OBSERVE THE INSTRUCTIONS GIVEN I...

Page 13: ...STORAGE a The product must be stored in a covered and dry place far away from heat sources and protected against dirt and vibrations b Protect the product against damp conditions heat sources and me c...

Page 14: ...orse Power 8 Hz Frequency 9 min 1 Speed of rotation 10 P N Pump item number 11 N Material code 12 MEI Index of the pump s quality in relation to its efficiency 13 Hyd Eff Hydraulic efficiency of the p...

Page 15: ...emove the delivery and suction caps before hooking the product up to the lines a Use metal or rigid plastic pipes in order to avoid their yielding because of the depression created at suction b suppor...

Page 16: ...5 M16 4 80 65 M16 8 80 EVM L 45 F 80 M16 8 80 80 M16 8 80 G 80 M16 8 80 80 M16 8 80 EVM L 64 F 100 M16 8 80 100 M20 8 100 G 100 M16 8 80 100 M20 8 100 Admissible strain on the flange Model Flange DN S...

Page 17: ...unning the pump without water inevitably causes serious damage to a number of the pump s internal parts Fill the pump with the terminal box closed and the power supply discon nected 10 1 FILLING PUMP...

Page 18: ...emptied Do not leave water deposits inside This opera tion must always be carried out whenever there is a chance of frost in order to avoid the breakdown of the pump components When performing repair...

Page 19: ...e nearest retailer DISPLAYED FAULT CAUSE SOLUTION THE PUMP STOPS AFTER WORKING FOR BRIEF PERIODS Pressure applications The difference between maximum and mi nimum pressure is minimal Increase the diff...

Page 20: ...fer less than other pumps built with materials of poorer quality though they are not entirely immune to the damage that cavitation brings Hence pumps must be installed in compliance with the laws of p...

Page 21: ...RATION OF EVM MOTOR DRIVEN PUMPS FIG 1 FIG 2 FIG 1 a Good immersion b Positive slope c Wide radius bend d Pipework with independent supports e Suction pipe diameter pump port diameter f Reducing coupl...

Page 22: ...0463 422782 2 2 Voir PLAQUE SIGNAL TIQUE chapitre 7 3 3 GARANTIE ET SERVICE APR S VENTE L INOBSERVATION DES INDICATIONS FOURNIES DANS CE LIVRET D INS TRUCTIONS ET OU UNE INTERVENTION VENTUELLE SUR LE...

Page 23: ...er Manutention de la pompe uniquement proc der comme pour l lectropompe la diff rence pr s qu il faudra fixer la sangle sur le support du moteur 5 2 STOCKAGE a Le produit doit tre conserv l abri dans...

Page 24: ...wer 8 Hz Fr quence 9 min 1 Vitesse de rotation 10 P N Code article pompe 11 N Code mat riaux 12 MEI Indice de rendement minimal de la pompe 13 Hyd Eff Efficacit hydraulique de la pompe 7 4 INFORMATION...

Page 25: ...ture du refoulement et de l aspiration avant de raccorder le produit aux tuyaux a Utiliser des tuyaux m talliques pour viter qu ils ne c dent sous la d pression qui se cr e en aspiration ou des tuyaux...

Page 26: ...L G 5 N 32 M10 2 30 EVMS L G 5 F 32 M16 4 70 EVMS L G 5 LF 32 M16 4 70 EVMS L G 10 N 40 M12 2 50 EVMS L G 10 F 40 M16 4 70 EVMS L G 10 LF 40 M16 4 70 EVMS L G 15 N 50 M12 2 50 EVMS L G 15 F 50 M16 4 7...

Page 27: ...ontre le fonc tionnement sec reli un flotteur des sondes ou un appareil quivalent Brancher en premier le conducteur de protection au bornier PE en le lais sant plus long afin qu il soit le dernier se...

Page 28: ...N ET R PARATION Toujours couper le courant avant d effectuer une op ration d entretien quelconque sur l lectropompe L lectropompe n exige pas d entretien ordinaire il est toutefois conseill de contr l...

Page 29: ...t ou remplacer le moteur par un autre plus puissant V rifier la puissance r elle absorb e par la pompe en fonction du liquide MANIFESTATION DE LA PANNE CAUSE REM DE LA POMPE S ARR TE APR S AVOIR FONCT...

Page 30: ...courant absorb d une valeur gale au facteur de correction T C Cote m a s l 1000 1500 2000 2500 40 1 0 96 0 94 0 90 45 0 95 0 92 0 90 0 88 50 0 92 0 90 0 87 0 85 55 0 88 0 85 0 83 0 81 60 0 83 0 82 0 8...

Page 31: ...maximal report sur la plaque le NPSHr augmente lorsque le d bit augmente au del de celui du rendement maximal e La temp rature de l eau est lev e avec 80 85 C il est fort probable que la pompe doive...

Page 32: ...ftssitz Via Campo Sportivo 30 38023 Cles TN ITALIA Telefono 0463 660411 Telefax 0463 422782 2 2 Siehe TYPENSCHILD Kapitel 7 3 3 GARANTIE UND TECHNISCHER KUNDENDIENST DIE NICHTBEACHTUNG DER ANWEISUNGE...

Page 33: ...otor entsprechend den Schritten der Pumpe mit Motor vorgehen den Gurt je doch am Motortr ger anbringen 5 2 LAGERUNG a Das Produkt muss in einem berdachten und trockenen Raum fern von W rmequellenundvo...

Page 34: ...rs in PS 8 Hz Frequenz 9 min 1 Drehzahl der Pumpe 10 P N Artikelnummer der Pumpe 11 N Materialnummer 12 MEI Mindesteffizienzindex 13 Hyd Eff Hydraulischer Wirkungsgrad der Pumpe 7 4 INFORMATIONEN ZUM...

Page 35: ...ichtigkeit pr fen Bei Lekagen die Pumpe entleeren und die Gleitringdichtung neu positionieren A 13 22 Bei auftretender Leckage von F rderfl ssigkeiten entfernen sie diese und positionieren sie die Kup...

Page 36: ...pe nicht ka vitiert 8 3 KR FTE UND ANZUGSDREHMOMENTE DER FLANSCHE Flansche Schraubenanzugsmomente Modelle Flansch DN Schraube Anz Bohrungen Drehmoment Nm EVMS L G 1 N 25 M10 2 30 EVMS L G 1 F 25 M12 4...

Page 37: ...tige gleichwertige Vorrichtung angeschlossen wird Schlie en Sie zuerst der Schutzleiteran die Klemme PE an und lassen Sie diesen l nger sodass er sich bei berm igem Zug an der Leitung als letz ter l s...

Page 38: ...Betriebsbedin gungen anhand von regelm igen Kontrollen zu berpr fen Intervalle rich ten sich nach der gepumpten Fl ssigkeit wobei vor allem auf ungew hnli che Ger usche und Vibrationen zu achten ist...

Page 39: ...h Drosse lung der Druckleitung ANZEICHEN URSACHE BEHEBUNG Der Klemmkasten ist der Sonne oder son stigen W rmequellen ausgesetzt Sch tzen Sie die Pumpe vor Sonne oder W rme quellen Fremdk rper blockier...

Page 40: ...e dem Korrekturfaktor entspricht T C H he m a s l 1000 1500 2000 2500 40 1 0 96 0 94 0 90 45 0 95 0 92 0 90 0 88 50 0 92 0 90 0 87 0 85 55 0 88 0 85 0 83 0 81 60 0 83 0 82 0 80 0 77 65 0 79 0 76 0 74...

Page 41: ...fgef hrte Beispiele k nnen Ansaugproblem verursachen a Die Saugh he ist zu gro sollte in der Praxis 7 8 m nicht berschrei ten b Die Saugleitung ist zu lang und oder hat zu viele B gen oder Ventile zu...

Page 42: ...les TN ITALIA Telefono 0463 660411 Telefax 0463 422782 2 2 V ase PLATA DATOS cap tulo 7 3 3 GARANT A Y ASISTENCIA T CNICA EL INCUMPLIMIENTO DE LAS INDICACIONES CONTENIDAS EN ESTE MA NUAL DE INSTRUCCIO...

Page 43: ...ien equilibrado al desplazarla CUIDADO Compruebe que el producto est bien fijado al motor y no se pueda volcar o caer Desplazamiento s lo de la bomba Seguir el mismo procedimiento que para la electrob...

Page 44: ...l eje 7 HP Potencia nominal del motor expresada en Hp horse power 8 Hz Frecuencia 9 min 1 Velocidad de rotaci n 10 P N C digo art culo bomba 11 N C digos de materiales 12 MEI ndice que mide la calidad...

Page 45: ...card n 4 tornillos A 14 24 Conectar definitivamente los tubos de env o y aspiraci n 25 Electrobomba instalada 8 2 ADVERTENCIAS GENERALES PARA LA INSTALACI N CUIDADO Quitar los tapones de cierre de en...

Page 46: ...5 M10 2 30 EVMS L G 1 F 25 M12 4 50 EVMS L G 1 LF 25 M12 4 50 EVMS L G 3 N 25 M10 2 30 EVMS L G 3 F 25 M12 4 50 EVMS L G 3 LF 25 M12 4 50 EVMS L G 5 N 32 M10 2 30 EVMS L G 5 F 32 M16 4 70 EVMS L G 5 L...

Page 47: ...o en seco que se debe conectar a un flotador a sondas o a otro instru mento equivalente Conectar primero el conductor de protecci n al borne PE dej ndolo m s largo para que este ltimo sea el que se se...

Page 48: ...mpa la alimentaci n el ctrica 12 MANTENIMIENTO Y REPARACI N Antes de realizar cualquier operaci n de manutenci n en la electrobomba desconectar la alimentaci n el ctrica La electrobomba no necesita ma...

Page 49: ...IO LA BOMBA SE DE TIENE DESPU S DE UN BREVE FUNCIO NAMIENTO debido a la activaci n de la protecci n t rmica Cuerpos extra os frenan la rotaci n de los rodetes Desmontar y limpiar la bomba Para esto co...

Page 50: ...79 0 76 0 74 0 72 15 3 TABLA DE PRESI N M XIMA DE EJERCICIO Presi n m xima de ejercicio Modelo bomba EVMS1 EVMS3 EVMS5 Hz 50 60 50 60 50 60 1 6 2 26 2 18 2 21 2 15 2 17 2 12 2 5 27 39 20 29 23 33 16 2...

Page 51: ...imo de placa el NPSHr aumenta al aumentar el caudal a un valor superior al de m ximo rendimiento e La temperatura del agua es elevada Con 80 85 C ya es probable que la bomba se deba colocar debajo del...

Page 52: ...TIE EN TECHNISCHE ONDERSTEUNING IN GEVAL VAN HET NIET IN ACHT NEMEN VAN DE AANWIJZINGEN IN DIT INSTRUCTIEBOEKJE EN OF EVENTUELE WERKZAAMHEDEN AAN HET PRO DUCT DIE NIET DOOR ONZE SERVICECENTERS ZIJN UI...

Page 53: ...ht goed in balans is tijdens de ver plaatsing LET OP Controleer of het product goed bevestigd is aan de motor en niet kan kantelen of vallen Verplaatsing van alleen de pomp Volg dezelfde procedure als...

Page 54: ...s 7 HP Nominaal vermogen van de motor uitgedrukt in Hp horse power paardekracht 8 Hz Frequentie 9 min 1 Rotatiesnelheid 10 P N Artikelcode pomp 11 N Materiaalcode 12 MEI Index die de pompkwaliteit mee...

Page 55: ...de afsluitdoppen aan de perszijde en de aanzuigzijde alvorens het product aan te sluiten op de leidingen a Metalen leidingen gebruiken om te vermijden dat deze het begeven tij dens de drukvermindering...

Page 56: ...PELS VAN DE FLENZEN Aanhaalkoppels van de flenzen Modellen Flens DN Schroef aant Schroef Aanhaalkoppel Nm EVMS L G 1 N 25 M10 2 30 EVMS L G 1 F 25 M12 4 50 EVMS L G 1 LF 25 M12 4 50 EVMS L G 3 N 25 M1...

Page 57: ...de frequentie van het netwerk overeenkomen met die van de motor die kunnen worden afgelezen van het typeplaatje Tussen het netwerk en de elektrische pomp moet een bedieningsbord wor den aangebracht m...

Page 58: ...kan dit schade aan de pomp zelf veroorzaken De werking van de pomp waarbij de stopkraan aan de perszijde meer dan een paar seconden gesloten is vermijden Bovendien is het continubedrijf van de pomp t...

Page 59: ...n door ongeschikte omvang van de lijn of van de kabels OPGETREDEN STORING OORZAAK OPLOSSING DE POMP STOPT NA KORT FUNCTIONEREN vanwege activering van de thermische beveiliging Thermische ijking ongesc...

Page 60: ...gelijk aan de correctiefactor T C Hoogte m a s l 1000 1500 2000 2500 40 1 0 96 0 94 0 90 45 0 95 0 92 0 90 0 88 50 0 92 0 90 0 87 0 85 55 0 88 0 85 0 83 0 81 60 0 83 0 82 0 80 0 77 65 0 79 0 76 0 74 0...

Page 61: ...het maxi mumdebiet aangegeven op het plaatje de NPSHr stijgt als het debiet stijgt en daarmee de maximale productiviteit overschrijdt e De temperatuur van het water hoog is bij 80 85 C is het al waars...

Page 62: ...A ZNAMIONOWA rozdzia 7 3 3 GWARANCJA I SERWIS TECHNICZNY NIESTOSOWANIE SI DO WSKAZ WEK ZAWARTYCH W NINIEJSZEJ IN STRUKCJI I LUB EWENTUALNE DZIA ANIA PODEJMOWANE NA PRODUK CIE PRZEZ PODMIOTY INNE NI NA...

Page 63: ...nej z t r nic e pasem nale y przypi wspornik silnika 5 2 PRZECHOWYWANIE a Produkt musi by przechowywany w pomieszczeniu zadaszonym i su chym z dala od r de ciep a brudu i drga b Chroni produkt przed w...

Page 64: ...w KM konie me chaniczne 8 Hz Cz stotliwo 9 min 1 Pr dko obrotowa 10 P N Kod pompy 11 N Kod materia w 12 MEI Wska nik mierz cy sprawno pompy w stosunku do jej wydajno ci 13 Hyd Eff Sprawno hydrauliczn...

Page 65: ...i w kt rej b d one zapa da si pod ci nieniem wytwarzanym przy zasysaniu w materiale pla stycznym o ma ym stopniu twardo ci b nale y podeprze oraz ustawi w poziomie przewody w taki spos b aby nie powod...

Page 66: ...0 EVMS L G 20 LF 50 M16 4 70 EVM L 32 F 65 M16 4 80 65 M16 8 80 G 65 M16 4 80 65 M16 8 80 EVM L 45 F 80 M16 8 80 80 M16 8 80 G 80 M16 8 80 80 M16 8 80 Modele Ko nierz DN ruba nr ruba Moment dokr cenia...

Page 67: ...nik podnie silnik tylko na tyle ile wystarczy do wykonania obrotu nie usuwaj c sprz g a pomi dzy wa em silnika a wa em pompy Na st pnie przykr ci z powrotem 4 ruby 10 NAPE NIANIE POMPY UWAGA Nie nale...

Page 68: ...dawa przybli on informacj co do dodatkowych prac konserwacyjno prewencyjnych dzi ki czemu pozwalaj unikn wyko nywania nieprzewidzianych napraw Do zalecanych dzia a przy wszelkich pracach konserwacyjny...

Page 69: ...silnika s zu yte Wymieni o yska W tym przypadku silnik jest r wnie g o ny USTERKA PRZYCZYNA RODKI ZARADCZE POMPA ZATRZYMUJE SI PO KR TKIM OKRESIE DZIA ANIA zadzia anie za bezpieczenia ter micznego Zb...

Page 70: ...alne ci nienie robocze Model pompy EVMS1 EVMS3 EVMS5 Hz 50 60 50 60 50 60 1 6 2 26 2 18 2 21 2 15 2 17 2 12 2 5 27 39 20 29 23 33 16 23 19 27 13 19 Maksymalne ci nienie robocze Model pompy EVMS10 EVMS...

Page 71: ...kresu wykaza nego na tabliczce NPSHr wzrasta kiedy zwi ksza si wydatek mimo zakresu maksymalnej sprawno ci e Wysoka jest temperatura wody przy 80 85 C pompa prawdopodobnie b dzie ju musia a by poni ej...

Page 72: ...0463 422782 2 2 B l m 7 3 AD PLAKASI na bak n 3 GARANT VE TEKN K SERV S BU KILAVUZDA VER LEN TAL MATLARA UYULMAMASI VE R NDE SER V S MERKEZLER M Z DI INDAK K LER N YAPMASI GARANT Y GE ERS Z KILAR VE R...

Page 73: ...ma Elektrikli pompayla ayn prosed r uygulay n Bu durumda kay n motor grubuna tak lmas gerekir 5 2 DEPOLAMA a r n s kaynaklar ndan uzakta kapal ve kuru bir ortamda depolanma l ve kire ve titre ime kar...

Page 74: ...otasyon h z 10 P N Pompa r n kodu 11 N Malzeme kodu 12 MEI Pompan n verimlili iyle ilgili kalite endeksi 13 Hid Ver Pompan n hidrolik verimlili i 7 4 YAYILAN G R LT HAKKINDA BILGILER G Kw Motor b y kl...

Page 75: ...ay n c esnek emme ve besleme borular kullan l yorsa t kanmalar n nlemek zere bunlar k v rmaktan ka n n d borular n olas ba lant lar na salmastra yap n emme borusuna hava girmesi pompan n i lemesini ne...

Page 76: ...L 64 F 100 M16 8 80 100 M20 8 100 G 100 M16 8 80 100 M20 8 100 Flan ta izin verilen gerilme Model Flan DN Gerilme X N Gerilme Y N Gerilme Z N EVMS L G 1 N 25 230 200 180 EVMS L G 1 F 25 230 200 180 E...

Page 77: ...men kapal olarak ger ekle t r lecek lem Belirtildi i gibi pompay susuz i letmek pompan n baz i komponentlerine geriye d n lemez ekilde ciddi hasarlar verir Terminal kutusu kapal ve elektrik beslemesi...

Page 78: ...ak pompay tamamen bo altman z temiz su ile zenli ekilde y kaman z bu do rultuda pompan n i inde su art klar kalmas ndan ka narak pompay bo altman z tavsiye edilir Bu i lem pompa komponentlerinin k r l...

Page 79: ...at c ya ba vurun ARIZANIN ORTAYA IKMASI NEDEN Z M POMPA KISA LE MELERDEN SONRA DURUYOR bas n uygulamalar Maksimum ve minimum bas n aras nda az fark ki bas n aras ndaki fark art r n POMPA DURMUYOR bas...

Page 80: ...er ile ger ekle tirilmi pompalara g re bu fenomene daha az maruz kal rlar ancak her hal karda kavitasyonun verdi i zararlardan ka nmalar m mk n de ildir Bu nedenle pompalar fizik kanunlar na ak kanlar...

Page 81: ...OMPALARIN DO RU I LEMESI I IN UYARILAR RES 1 RES 2 RES 1 a yi dalma b Pozitif e im c Geni yar apl e ri d Ba ms z destekli borular e Emme borusu ap pompa a z ap f Eksantriklerde red ksiyon RES 2 a Yete...

Page 82: ...N DES L ORIGINAL Wir die Firma EBARA PUMPS EUROPE S p A mit Sitz in Via Campo Sportivo 30 38023 Cles TN ITALIEN erkl ren hiermit auf eigene Verantwor tung dass unsere Produkte auf welche sich diese Er...

Page 83: ...minimalnym wska niku efektywno ci MEI patrz tabliczka znamionowa Pompy i nast puj cych zharmonizowanych normach technicznych EN 809 EN ISO 12100 EN 60204 1 EN 60034 30 1 oraz innych normach maj cych...

Page 84: ...r mount lift up so the coupling is snug against the shaft end tighten the coupling bolts evenly to the specified torque Standard assembly is for the terminal box to be positioned over the discharge se...

Page 85: ...85 12 3 Nm 13 14 9 16 Note Refer to instruction manual supplied with pump A B D C 0 5 mm A B 0 5 mm 0 5 mm C D 0 5 mm A 8 10 11...

Page 86: ...Single phase with motor protector FR Monophas avec protection moteur DE Einphasig mit Motor berlastschutz ES Monof sico con motoprotector NL Monofase met motorbeveiliging PL Jednofazowa z zabezpieczen...

Page 87: ...ap 10 2 NL hfdst 10 2 PL rozdz 10 2 TR bol 10 2 IT cap 10 1 EN chap 10 1 FR chap 10 1 DE kap 10 1 ES cap 10 NL hfdst 10 1 PL rozdz 10 1 TR bol 10 1 IT cap 11 2 EN chap 11 2 FR chap 11 2 DE kap 11 2 ES...

Page 88: ...88 1 2 3 4 5 6 7 8 9 10 12 D EVMS 1 3 5 10 15 20 4 kW 3 Nm M6 15 Nm 11...

Page 89: ...89 D EVMS 1 3 5 10 15 20 5 5 kW 1 2 3 4 5 6 7 8 9 10 11 12 3 Nm M8 18 Nm M10 50 Nm...

Page 90: ...90 1 2 3 4 5 6 7 8 9 10 11 12 13 14 D EVM 32 45 64 with bearing 5 7 Nm...

Page 91: ...91 1 2 3 4 5 6 7 8 9 10 11 12 13 14 D EVM 32 45 64 without bearing 5 7 Nm...

Page 92: ...z Hz 8 Pole 9 Art Nr Materialien 10 Art Nr Teile aus Gummi 11 kW Motor 12 Motorphasen 13 Trennungsstrich 14 Anzahl Laufr der reduziert ES 1 Tipo de bomba 2 C digo del modelo de serie 3 Caudal nominal...

Page 93: ...93...

Page 94: ...94...

Page 95: ...95...

Page 96: ...el 48 22 3909920 Fax 48 22 3909929 e mail mktgpl ebaraeurope com EBARA Pumps Europe S p A GERMANY Elisabeth Selbert Stra e 2 63110 Rodgau Germany Tel 49 0 6106 66099 0 Fax 49 0 6106 66099 45 e mail mk...

Reviews: