Installation 

 

 

 

1. Confirmation before installation 
 

Measurement of insulation resistance 

Measure  the  insulation  resistance  between  the  ground  and  the  grounding  wire  and  between 
phases  using  a  megger  in  a  state  that  the  motor  and  the  cables  (excluding  the  power  source 
connection section) are immersed in water. If the insulation resistance at the respective sections 
is  20M

Ω  or  more,  there  is  no  problem.  During  the  measurement,  keep  the  power  source 

connection section of cables distant from the ground. 

 

2. Installation 

 

Warning

 

On handling and installation work of the pump, assure safety by confirming the 
mass  and  the  shape  of  the  pump  referring  to  the  appearance  this  instruction 
manual,  drawing,  the  catalogue,  and  other  materials.  There  are  dangers  of 
dropping the pump and the injury of worker. 

 

Never execute the operation of the pump and the mounting work of parts in a 
lifted position. That type of work is dangerous causing dropping the pump and 
injury of workers. 

 

Do  not  damage,  break,  machine,  forcefully  bend,  stretch,  or  twist  the  power 
cable, bind the power cable into a bundle, or place a heavy load on the power 
cable. Those kinds of handling cause fire and electric shock 

 

The  handling  and  installation  work  of  the  pump  shall  be  done  only  by  a 
qualified technician in accordance with the applicable legal standards.    Unless 
follow  the  rule,  the  work  becomes  illegal  and  there  is  a  possibility  of  inducing 
accident such as fire and injury. 

 

 

Note 

Apply repair painting at an interval depending on the use environment. Depending on the 
use  environment,  there  may  be  generated  rust  at  threaded  sections,  machined  sections 
with rust-proof coating, rust-proofing sections, etc. 

1) 

On transporting and installing the pump, never apply tension to the cables. Those works shall be 
done by attaching chain or rope to the handle. 

 

2) 

The  pump  cannot  be  operated  in  horizontal  position  and  in  lifted  position.  Operate  the  pump  at 
vertical position on a base. 

3) 

Install  the  pump  at  a  place  of  free  from  turbulence  in  the  tank,  as  far  as  possible.  For  a  pump 
equipped with a float, select the place of installation of the pump so as to avoid direct hitting of the 
flowing-down liquid to protect the float. 

4) 

If there is a flow in the tank, support the pipe at an adequate position, (refer to Fig. 2). 

5) 

Avoid the generation of air-pocket in the pipe. 

6) 

Do  not  immerse  the  discharge  end  of  the  pipe  in  water.  Immersed  end  of  the  pipe  induces 
backflow on stopping the operation of the pump. 

7) 

Apply a sewage check valve to every pump. 

8) 

Since non-Automatic type pump (Model DL) has no Automatic operation device which is actuated 
by a float in the pump, care shall be given to the pump operating water level. If that type of pump 
is operated continuously for 10 minutes or longer period at near the operable minimum water level, 
the Auto-cut in the motor is actuated. Therefore, the Automatic operation device shall be installed 
as illustrated in Fig. 3, and the stop-operation water level shall be set at a position higher than the 
operable minimum water level to avoid dry operation. The operation-start water level shall be set 
to a position higher than the level of fully immersing the pump. 

 
 
 
 
 
 

Summary of Contents for DL

Page 1: ...ion when protective device is activated 15 Installation 8 1 Confirmation before installation 8 Troubleshooting 17 2 Installation 8 Structure 18 3 Electric wiring 10 1 Sectional view 18 Operation 12 10...

Page 2: ...ontents shall be observed in any case Description of the indication Terms of warning Description Warning Wrong handling expects to raise a danger resulting in death or serious injury of the operator C...

Page 3: ...sassembling repairing and modifying the pump shall be limited to a repair technician There is a possibility of injury caused by electric shock ignition abnormal functioning trouble etc Before entering...

Page 4: ...nt or by leakage of enclosed liquid from mechanical seal Do not use the pump at an important facility computer cooling apparatus cooling apparatus for refrigerator etc Since machining oil rubber relea...

Page 5: ...the nameplate Specifically care shall be paid on the frequency 50 Hz or 60 Hz Caution Do not operate a pump of 50Hz at 60Hz The operation at wrong frequency induces pump break caused by excess pressur...

Page 6: ...clusion of foreign matter Do not use the pump at facilities for organisms fish farm fish preserve aquarium etc There is a possibility of extinction of organisms caused by leak current or by leakage of...

Page 7: ...side Ceramics carbon sliding material at motor side NBR rubber material Turbine oil ISO VG 32 Motor 1 2 Model number of poles Thermal class Phase frequency voltage current Built in protective device D...

Page 8: ...erval depending on the use environment Depending on the use environment there may be generated rust at threaded sections machined sections with rust proof coating rust proofing sections etc 1 On trans...

Page 9: ...his will not happen 13 Models DLA and DLJ will undergo automatic alternate operation only when they are paired Position the floats for these automatic alternate operation pumps DLJ as shown in Fig 5 T...

Page 10: ...needs to be provided in the final installation It is recommended to use a circuit breaker as main breaker that is suitable for isolation according to appropriate legal standard EN60947 2 and is equip...

Page 11: ...el E among the four lines as shown in Fig 7 Never connect the Green and Yellow stripe cord or the Green cord to the power source The grinding shall be surely conducted conforming to the Technology Sta...

Page 12: ...ition or at near the operable minimum water level the Auto cut in the motor is actuated If the situation is repeated the pump life becomes short Once the Auto cut is actuated the motor does not start...

Page 13: ...the pumps are now ready for operation Note Operate the pump at a discharge rate suitable for the facilities Operation at excessively small or large capacity causes noise and vibration and consumes unn...

Page 14: ...hin the limit of pump rating the pump may have caught foreign matter 2 If the discharge rate showed a sudden decrease foreign matter may have clogged the suction opening 2 Regular inspection 1 Once a...

Page 15: ...t every disassembly for inspection Every 20000 cycles of operation Every 100000 cycles of operation Expected replacement time One year or 6000 hours of total operating hours either of shorter one Once...

Page 16: ...and water to a container Then clean the inside the leakage detector s chamber and motor chamber and replace the mechanical seal as well as gaskets and O rings Leakage Detector Contact rating AC280V 0...

Page 17: ...ace the mechanical seal Liquid quality and operation conditions need to be reviewed Replace the mechanical seal Pumping not effected or insufficient pumping capacity Pump running in reverse rotation G...

Page 18: ...L SEAL 1 SET 811 SUBMERSIBLE CABLE 1 115 1 O RING 1 814 MOTOR FRAME 1 115 2 O RING 1 816 BRACKET 1 115 3 O RING 1 817 BRACKET 1 117 1 GASKET 1 830 SHAFT 1 117 2 SEAL WATER 1 849 1 BALL BEARING 1 120 1...

Page 19: ...without contacting with the suction cover Then enter the operation of the pump 11 Limited Warranty EBARA Corporation warrants to the original retail purchaser Customer the followings 1 This warranty v...

Page 20: ...uires about the pump please contact EBARA Singapore Ebara Engineering Singapore Pte Ltd Website www ebara com sg E mail ebaranet singnet com sg Malaysia Ebara Pumps Malaysia Sdn Bhd Website www ebara...

Reviews: