- 16 -
2
)
When leakage detector is activated
Lift the pump out and set upright. Remove the plug of the
leakage detector
’s chamber and drain the oil and water to a
container. Then clean the inside the leakage detector
’s
chamber and motor chamber, and replace the mechanical
seal as well as gaskets and O-rings.
Leakage Detector
Contact rating
AC280V, 0.5A AC50VA
Contact type
Break Contact
(Normal: on, At temp. rise: OFF)
Contact Cable
2 cores
H07RIV-F
,Cab-tyre Cable
1.0mm
2.
Blue,Brown (non-polarity)