EBARA DL Instruction Manual Download Page 12

 

 

- 12 - 

b) Thermal protector 

 

The motor (standard 11kW or larger and special model of 2.2kW~7.5kW) has a built-in thermal 

protector  that  outputs  signals  via  a  cable.  Connect  the  thermal  protector  cable

’s  wires  to  the 

control panel in accordance with the specifications in the table on the right, so that the pump will 

be stopped if the motor

’s internal temperature rises too high. 

Use this protector in combination with a 3E relay or similar for phase failure. 

 

 

Operation 

   

 

 
 
Warning 
 

During  the  operation  of  the  pump,  do  not  insert  hand  or  foot  in  the  suction  opening  of 
the pump to avoid injury at the rotary section. 

 

Never operate the pump in water in the presence of personnel. 
If electric leak occurs, the personnel may suffer electric shock. 

 

Do  not  execute  dry  operation  in  air.  That  type  of  operation  causes  deterioration  in 
insulation to lead to electric shock and electric leak. 

 

1. Before starting 

1)  After  completing  the  installation  work,  measure  again  the  insulation  resistance  in  accordance  with 

-1 "Confirmation before installation". 

2) Confirm that the water level is satisfactory. If the pump is operated for a long period of time under dry 

condition  or  at  near  the  operable  minimum  water  level,  the  Auto-cut  in  the  motor  is  actuated.  If  the 

situation is repeated, the pump life becomes short. Once the Auto-cut is actuated, the motor does not 

start until it is cooled. (Even during the period of Auto-cut functioning, the power is supplied up to the 

pump. Since the pump  will restart  without indication, the  inspection shall be  given after cut OFF the 

power source.) 

3) Operate the pump within the range given in the chart. 

4) Frequent start-stop operations damage the pump in early stage of life. Limit the starting frequencies 

as below. 

Motor out put 

Less than 7.5kW 

11~22kW 

Frequencies of starting 

Ten times per hour 

Six times per hour 

2. Test operation

 

  Non-automatic type pump (Model DL)  

         

             

…   

Automatic type pump (Model DLA)

 

1)  Turn  the  switches  1  -  2  on  and  off  a  couple  of  times 

with  the  gate  valve  slightly  opened  to  check  that  it 

starts  up  normally.    It  should  be  noted  that  a  DLA 

model  pump  does  not  start  unless  the  upper  float  is 

positioned up. 

2)  Next, check the direction of rotation.    Reverse direction of rotation is indicated by low capacity and 

abnormal  noise  and  vibration.    If  the  pump  is  found  to  be  running  in  reverse  rotation,  change 

around the onnections of 2 of the 3 phases to obtain the regular rotation direction (See Fig. 8). 

 

 

 

Fig. 5 

Switch box 

Motor 

Motor 

U1  V1  W1 

W1 

V1  U1 

Switch box 

Fig. 8 

Summary of Contents for DL

Page 1: ...ion when protective device is activated 15 Installation 8 1 Confirmation before installation 8 Troubleshooting 17 2 Installation 8 Structure 18 3 Electric wiring 10 1 Sectional view 18 Operation 12 10...

Page 2: ...ontents shall be observed in any case Description of the indication Terms of warning Description Warning Wrong handling expects to raise a danger resulting in death or serious injury of the operator C...

Page 3: ...sassembling repairing and modifying the pump shall be limited to a repair technician There is a possibility of injury caused by electric shock ignition abnormal functioning trouble etc Before entering...

Page 4: ...nt or by leakage of enclosed liquid from mechanical seal Do not use the pump at an important facility computer cooling apparatus cooling apparatus for refrigerator etc Since machining oil rubber relea...

Page 5: ...the nameplate Specifically care shall be paid on the frequency 50 Hz or 60 Hz Caution Do not operate a pump of 50Hz at 60Hz The operation at wrong frequency induces pump break caused by excess pressur...

Page 6: ...clusion of foreign matter Do not use the pump at facilities for organisms fish farm fish preserve aquarium etc There is a possibility of extinction of organisms caused by leak current or by leakage of...

Page 7: ...side Ceramics carbon sliding material at motor side NBR rubber material Turbine oil ISO VG 32 Motor 1 2 Model number of poles Thermal class Phase frequency voltage current Built in protective device D...

Page 8: ...erval depending on the use environment Depending on the use environment there may be generated rust at threaded sections machined sections with rust proof coating rust proofing sections etc 1 On trans...

Page 9: ...his will not happen 13 Models DLA and DLJ will undergo automatic alternate operation only when they are paired Position the floats for these automatic alternate operation pumps DLJ as shown in Fig 5 T...

Page 10: ...needs to be provided in the final installation It is recommended to use a circuit breaker as main breaker that is suitable for isolation according to appropriate legal standard EN60947 2 and is equip...

Page 11: ...el E among the four lines as shown in Fig 7 Never connect the Green and Yellow stripe cord or the Green cord to the power source The grinding shall be surely conducted conforming to the Technology Sta...

Page 12: ...ition or at near the operable minimum water level the Auto cut in the motor is actuated If the situation is repeated the pump life becomes short Once the Auto cut is actuated the motor does not start...

Page 13: ...the pumps are now ready for operation Note Operate the pump at a discharge rate suitable for the facilities Operation at excessively small or large capacity causes noise and vibration and consumes unn...

Page 14: ...hin the limit of pump rating the pump may have caught foreign matter 2 If the discharge rate showed a sudden decrease foreign matter may have clogged the suction opening 2 Regular inspection 1 Once a...

Page 15: ...t every disassembly for inspection Every 20000 cycles of operation Every 100000 cycles of operation Expected replacement time One year or 6000 hours of total operating hours either of shorter one Once...

Page 16: ...and water to a container Then clean the inside the leakage detector s chamber and motor chamber and replace the mechanical seal as well as gaskets and O rings Leakage Detector Contact rating AC280V 0...

Page 17: ...ace the mechanical seal Liquid quality and operation conditions need to be reviewed Replace the mechanical seal Pumping not effected or insufficient pumping capacity Pump running in reverse rotation G...

Page 18: ...L SEAL 1 SET 811 SUBMERSIBLE CABLE 1 115 1 O RING 1 814 MOTOR FRAME 1 115 2 O RING 1 816 BRACKET 1 115 3 O RING 1 817 BRACKET 1 117 1 GASKET 1 830 SHAFT 1 117 2 SEAL WATER 1 849 1 BALL BEARING 1 120 1...

Page 19: ...without contacting with the suction cover Then enter the operation of the pump 11 Limited Warranty EBARA Corporation warrants to the original retail purchaser Customer the followings 1 This warranty v...

Page 20: ...uires about the pump please contact EBARA Singapore Ebara Engineering Singapore Pte Ltd Website www ebara com sg E mail ebaranet singnet com sg Malaysia Ebara Pumps Malaysia Sdn Bhd Website www ebara...

Reviews: