(I)
Appendix 1
Material Safety Data Sheet Vacuum Pump Oil
INLAND VACUUM INDUSTRIES -- FOMBLIN Y-LVAC 25-6
MATERIAL SAFETY DATA SHEET
NSN: 915000F045542
Manufacturer's CAGE: 59149
Part No. Indicator: A
Part Number/Trade Name: FOMBLIN Y-LVAC 25/6
===========================================================================
General Information
===========================================================================
Company's Name: INLAND VACUUM INDUSTRIES INC
Company's Street: 35 HOWARD AVE
Company's P. O. Box: 373
Company's City: CHURCHVILLE
Company's State: NY
Company's Country: US
Company's Zip Code: 14428
Company's Emerg Ph #: 716-293-3330
Company's Info Ph #: 716-293-3330
Record No. For Safety Entry: 001
Tot Safety Entries This Stk#: 001
Status: SE
Date MSDS Prepared: 01OCT92
Safety Data Review Date: 08DEC95
Preparer's Company: INLAND VACUUM INDUSTRIES INC
Preparer's St Or P. O. Box: 35 HOWARD AVE
Preparer's City: CHURCHVILLE
Preparer's State: NY
Preparer's Zip Code: 14428
MSDS Serial Number: BYQMW
===========================================================================
Ingredients/Identity Information
===========================================================================
Proprietary: NO
Ingredient: 1-PROPENE 1,1,2,3,3,3-HEXAFLUORO-OXIDIZED, POLYMD. FOMBLIN Y
*95-4*
Ingredient Sequence Number: 01
NIOSH (RTECS) Number: 1008240PH
CAS Number: 69991-67-9
===========================================================================
Physical/Chemical Characteristics
===========================================================================
Appearance And Odor: CLEAR COLORLESS LIQUID W/NO ODOR
Boiling Point: >518F
Vapor Pressure (MM Hg/70 F): <0.01
Specific Gravity: 1.9
Solubility In Water: INSOLUBLE
Percent Volatiles By Volume: 0
===========================================================================
Fire and Explosion Hazard Data
===========================================================================
Flash Point: NONE
Special Fire Fighting Proc: KEEP CONTAINERS COOL BY SPRAYING W/WATER WHEN
EXPOSED TO FIRE, IF FLAMES HAVE REACHED THE PRODUCT CAUSING A POSSIBLE
DECOMPOSITON YIELDING, USE SCBA.
Unusual Fire And Expl Hazrds: NONE
===========================================================================
EBARA
Corporation
Summary of Contents for A07V
Page 9: ...vii EBARA Corporation...
Page 10: ...viii EBARA Corporation...
Page 11: ...ix EBARA Corporation...
Page 14: ...xii Blank page EBARA Corporation...
Page 21: ...7 EBARA Corporation Outline Drawing A70W...
Page 22: ...8 Outline Drawing A30W EBARA Corporation...
Page 23: ...9 EBARA Corporation Outline Drawing A25S...
Page 24: ...10 EBARA Corporation Outline Drawing A10S...
Page 25: ...11 EBARA Corporation Outline Drawing A07V...
Page 60: ...46 Blank Page EBARA Corporation...
Page 63: ...III Label Country US Label Emergency Number 716 293 3330 EBARA Corporation...