Malfunctions
22
14 Malfunctions
Errors
Possible cause
Remedy
Still water
Water jet is too weak
Water pressure is too low
Adjust the water pressure (mini-
mum water pressure = 1.5 bar).
Water jet is too strong
Water pressure is too high
Set the pressure reducer (
Max. 3.0 bar
Carbonated water
Water jet is too weak
Flow rate is set too low
Set the flow meter (
Water jet sprays too much
Flow rate is set too high
Set the flow meter (
Water does not contain
enough carbonic acid
Air in the carbonator tank
Vent the carbonator tank (
Gas pressure too low
Increase gas pressure (
Water hardness is not optimal
Soften the water.
Optimal: 5-20 °dH
Inlet water temperature is too
high (max. 35°C)
Connect water dispenser too cold
water.
Refrigeration not set
Set the refrigeration (
Withdrawal quantity too high
Draw a maximum of 20 l per hour.
Flow rate is set too high
Set the flow meter (
LED blinks slowly
Carbonic acid supply is closed
Open the valve on the carbonic
acid bottle.
Gas pressure too low
Increase gas pressure (
LED blinks quickly
Water stop cock is closed
Open the water stop cock.
Water flow pressure is too low
Set the pressure reducer (
Max. 3.0 bar
Hygiene filter is exhausted
Replace the hygiene filter.
Carbonic acid bottle empties too quickly
Leaking gas system
Check gas system for leakages
(
UVC lamp does not light up
Ignition failure
Spatially separate the lamp from
the cable.
Inverter defective
Check inverter function,
if necessary, replace.
Lamp defective
Replace lamp.
Discoloured water hoses
Iron concentration in water is
too high
Measure the iron concentration.
Replace the hose.
Microbiological cause
Draw a sterile water sample and
analyse. Water sample must
reach laboratory within 24 hours.