Setting the water dispenser
15
7
Setting the water dispenser
7.1 Setting the flow regulator for carbonated water
The amount of water which is drawn per unit of time is set on the flow regulator (1).
Factory setting: 200 ml in 8 seconds (1.5 l/min = 150 ml/6 s)
Clockwise rotation: Flow rate is reduced
Anti-clockwise rotation: Flow rate is increased
IMPORTANT
After each hygiene maintenance, the flow rate must be reset correctly. If the flow rate is too
high, the carbonator tank will run empty. The pump will stop after 4 minutes to prevent it
from running dry. Restarting the pump: Pull the plug and plug back in after 3 seconds.
Completely close the flow regulator (1) (clockwise rotation).
Open the flow regulator (1) with 2 rotations.
Draw carbonated water and test it:
Does approx. 200 ml of water flow out in 8 seconds?
Is the carbonation of the water correct?
Summary of Contents for Acqua 80