12
XSTORAGE HOME 3P INSTALLATION MANUAL
MN700009EN August 2020 www.eaton.com
00 Title
Figure 9. xStorage Home 3P system installation
xStorage Home 3P
PV1
N
N
L1
L2
L3
L3
L2
RCD
RCD
L1
N
L1 L2 L3
PE
PE
PE
L3
L2
L1
N
PE
N
L1 L2 L3
PE
PE
BMS
BAT
PV2
1
2
3
3
6
7
4
5
Number Description
1
AC grid
2
Emergency power supply (EPS)
3
Energy meter
4
External interlock system
5
Battery
6
Home loads or non-critical loads
7
Privileged loads or critical loads
Ground connection to PE on the neutral conductor (N) where required by law