30
XSTORAGE HOME 3P USER MANUAL
MN700011EN December 2020 www.eaton.com
E003
TYPE
SOLUTION
E034
Converter control system fault.
Switch off and restart the system.
Refer to the sections “System switching off” and “System
switching on”.
If the problem persists, please contact Eaton technical support
representative.
E035
Converter control system fault.
Switch off and restart the system.
Refer to the sections “System switching off” and “System
switching on”.
If the problem persists, please contact Eaton technical support
representative.
E036
Battery temperature out of range (only
LEAD ACID).
Check visually the presence and connections of the battery
temperature sensor (lead-acid battery).
Check visually that the ambient temperature is within the
allowed range.
Check visually the correct positioning of the battery and that
the installation complies with the requirements contained in
this manual.
Refer to the section “Electrical connections”.
If the problem persists, please contact Eaton technical support
representative.
E037
Converter control system fault.
Switch off and restart the system.
Refer to the sections “System switching off” and “System
switching on”.
If the problem persists, please contact Eaton technical support
representative.
E038
Converter control system fault.
Switch off and restart the system.
Refer to the sections “System switching off” and “System
switching on”.
If the problem persists, please contact Eaton technical support
representative.
E001LI ÷
E0031LI
Lithium-ion battery alarms from battery
BMS.
Check visually the connections and polarity at the BATTERY
inputs of the system.
If the problem persists, contact your Eaton technical support
representative.
W001LI ÷
W0031LI
Lithium-ion battery warnings from
battery BMS.
Check visually the connections and polarity at the BATTERY
inputs of the system.
If the problem persists, please contact Eaton technical support
representative.
EV001LI ÷
EV0031LI
Lithium-ion battery messaging from
battery BMS.
Check visually the connections and polarity at the BATTERY
inputs of the system.
If the problem persists, please contact Eaton technical support
representative.