5
EATON
IB500014EN
Installation instructions
Installation Instructions – Caretaker
Figure 12.
Figure 13.
(3) O-Ring Screw Retainers
(3) #8-32 X 3/8” Screws
Drop House Side Shield
Optional Drop Shield House Side Shield
Tools Required:
1/4” Socket or flathead screw driver.
1. Insert provided thread forming screws into house side shield mounting locations and place provided O-rings over screw
threads to hold screws within House Side Shield. Install house side shield onto housing. (Figure 12.)
ote:
N
There are four positions for the House Side Shield at 90° increments.
Optional Drop Shield House Side Shield with SR
Refractor
Tools Required:
1/4” socket or flathead screwdriver.
1. If using the Drop House Side Shield with the SR
Refractor, slide the drop house side shield in the
desired position within the SR refractor.
2. Insert provided thread forming screws into refractor
and house side shield and place provided O-rings over
screw threads to hold screws within Drop House Side
Shield and SR Refractor.
3. Install SR refractor in the die-cast housing in the two
side mounting locations. (Figure 13.)
MAINTENANCE NOTE:
A regular maintenance schedule
should be followed to retain optimal light output and
thermal performance. Optical lens cleaning should be
performed with a clean dry cloth to remove any dust or
other contaminants. Additional cleaning can be performed
with non-abrasive cleanser.
SR Refractor
O-Ring Screw
Retainer
Drop House Side
Shield (Optional)
#8-32 X1/2” Screws