Settings Options and Partitions Menus
Page 74
c) By activating a Final Exit zone allocated to the partition (to start an entry timer) and
then entering an access code or presenting a proximity tag to a keypad.
Note:
This
method does not comply with BS8243 clause 6.4.
As Partition 1
This option appears for all partitions except partition 1. If you select this option, the
partition will use the same exit mode as partition 1.
Settle Time
This option is available only if
Exit Mode
is set to Final Door Set, Lock Set or Exit
Terminate. This option allows you to define a time delay to allow detectors to settle before
the system sets. During this period, the sounders stop and the control unit ignores any
alarms generated by the detectors.
Enter two digits to specify a time in seconds, from 01 to 30. The default is 15 seconds to
allow radio PIRs to send all the transmissions required to indicated that they are settled.
Exit Time
This option is available only if
Exit Mode
is set to Timed Set or Silent Set. The exit time
can take any value between 10s and 120s.
Entry Time
The entry time can take any value between 10s and 120s. The entry time you select in this
option applies to full set and all part sets.
To comply with EN50131-1 Clause 8.3.8.2, maximum is 45s for Entry Time.
Alarm Response
Note:
In a part-setting system, the response for a full set is always Siren + Comms.
Internal
Keypads and loudspeakers.
Siren
Keypads, loudspeakers and siren.
Siren + Comms
Keypads, loudspeakers, siren and communication. Note that any Siren Delay (see
page 77) applies to Siren+Comms, but not Internal or Siren alarm responses.
HUA Response
This option controls the audible alarm associated with Hold-Up Alarms (HUAs).
Audible
The control unit starts HUA alarm tones from the keypads and loudspeakers
assigned to the partition in which the alarm occurs, and activates any siren outputs.
The sirens follow the
Siren Time
(see page 75). The loudspeakers operate until a
user silences the alarm.
Silent
The control unit keeps the HUA alarm silent: there are no alarm tones from keypads
or loudspeakers and any siren outputs or HUA outputs remain inactive.