background image

GridAdvisor™ Series II smart sensor installation instructions

IL915001EN

April 2019

Eaton.com

3

Safety for life

Eaton meets or exceed all applicable industry standards relating to product safety in its products. We actively promote safe 
practices in the use and maintenance of our products through our service literature, instructional training programs, and the 
continuous efforts of all Eaton’s employees involved in product design, manufacture, marketing, and service.

We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around 
high voltage lines and equipment and support our 

Safety For Life

 mission.

Safety information

The instructions in this manual are not intended as a 
substitute for proper training or adequate experience in the 
safe installation, operation, servicing and testing of the 
equipment described. Only competent technicians who are 
familiar with this equipment and these instructions should 
install, operate, service and test it.

A competent technician has qualifications including:

Is thoroughly familiar with these instructions and 
equipment.

Is trained in industry-accepted high- and low-voltage safe 
operating practices and procedures.

Is trained in the care and use of protective equipment such 
as arc flash clothing, safety glasses, face shield, hard hat, 
rubber gloves, clampstick, hotstick, etc. 

Following is important safety information. For safe 
installation and operation of this equipment, read and follow 
all cautions and instructions.

This manual may contain four types of hazard statements:

Indicates a hazardous situation which, if not avoided,
will result in death or serious injury.

Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.

Indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury or equipment damage.

Indicates a hazardous situation which, if not avoided, may
result in equipment damage only.

Safety instructions

Following are general caution and warning statements that apply 
to this equipment. Additional statements, related to specific 
tasks and procedures, are located throughout the document.

Hazardous voltages are present. 

Death, personal injury and equipment damage, can
result if safety precautions are not followed. 

Use authorized utility safety procedures to install, test,
and service the GridAdvisor series II smart sensor.

Before installing, operating, maintaining, or testing this
equipment, carefully read and understand the contents
of this document. 

Improper operation, handling, or maintenance can result
in death, severe personal injury and equipment damage.

This equipment is not intended to protect human life. 

Follow all locally approved procedures and safety
practices when installing or operating this equipment. 

Failure to comply may result in death, severe personal
injury and equipment damage.

Hazard Statement Definitions

Summary of Contents for GridAdvisor II Series

Page 1: ...IL915001EN GridAdvisor Series II smart sensor installation instructions Effective April 2019 Supersedes August 2017 Energy Automation Solutions ...

Page 2: ...SHALL NOT BECOME PART OF OR MODIFY ANY SUCH PRIOR OR EXISTING AGREEMENT The information recommendations descriptions and safety notations are based on Eaton experience and judgment THIS INFORMATION SHOULD NOT BE CONSIDERED AS ALL INCLUSIVE OR COVERING ALL CONTINGENCIES If further information is required Eaton should be consulted In no event will Eaton be responsible to the user in contract in tort...

Page 3: ...lampstick hotstick etc Following is important safety information For safe installation and operation of this equipment read and follow all cautions and instructions This manual may contain four types of hazard statements Indicates a hazardous situation which if not avoided will result in death or serious injury Indicates a hazardous situation which if not avoided could result in death or serious i...

Page 4: ...ile a claim with the carrier immediately Handling Be careful during handling and storage of the sensor to minimize the possibility of damage If the sensor is to be stored for any length of time prior to installation provide a clean dry storage area Quality standards ISO 9001 certified quality management system Installation procedures SIM cards A SIM card is a small removable card consisting of an ...

Page 5: ...disconnect of ProView NXG software 5 OTASP may take up to five 5 minutes with included retries so do not the remove battery from the sensor within this time frame 6 OTASP results can be confirmed in the sensor s communication logs with the ProView NXG software Note If the OTASP process fails and the sensor blinks red LEDs continuously check the communication log for diagnostics OTASP can fail if s...

Page 6: ... The exact trip value is dependent on the overall diameter of the double back neutral wires Figure 2 Recommended methods of concentric neutral primary cable preparation Method 2 refer to Figure 2B 1 Attach one or two strands of the concentric neutral wrapped around the cable to the tie off tab on the elbow 2 Terminate all of the remaining neutral wires just below the elbow The balance of the neutr...

Page 7: ...a location shown in Figure 4 while holding the hotstick horizontal The triggering mechanism will release the clamping arms and securely attach the device to the cable Note Only the closed core current transformer CT need be applied over the region of the cable where the concentric neutral has been removed or double backed Figure 5 For installation on tape shield cable the closed core CT of the sen...

Page 8: ...e annunciation during the installation of device to verify proper load current is present Programming sensor Refer to the GridAdvisor Series II Smart Sensor ProView NXG software programming manual MN915003EN for instructions on connecting to the sensor with the Bluetooth module and or programming device with ProView NXG software Load LED Source LED Table 1 GridAdvisor Series II Smart Sensor LEDs P...

Page 9: ...uence steps Action LED Behavior First reed switch activation After 10 seconds if no further reed switch closure occurred the Bluetooth radio will be turned on enter discoverable mode and wait for a connection Load and Source LEDs will flash a simultaneous blue sequence After 10 seconds the Load and Source LEDs will light solid for 2 seconds indicating that Bluetooth functionality is active You may...

Page 10: ...eived including interference that may cause undesired operation Anatel Anatel homologation 3670 15 8433 01 07898994273486 GridAdvisor Model E0013X41G10 Este equipamento opera em caráter secundário isto é não tem direito a proteção contra interferência prejudicial mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário This equipment operates on a sec...

Page 11: ...GridAdvisor Series II smart sensor installation instructions IL915001EN April 2019 Eaton com 11 Regulatory information ...

Page 12: ...utomation Solutions Division 3033 Campus Drive Suite 350N Minneapolis MN 55441 United States Eaton com 2019 Eaton All Rights Reserved Printed in USA Publication No IL915001EN Rev 3 April 2019 Eaton is a registered trademark All other trademarks are property of their respective owners For GridAdvisor series II smart sensor product information call 1 877 277 4636 or visit Eaton com ...

Reviews: