The user alone is responsible for the appro­
priate use of this plug and socket system. 

After a short in the circuit, the operative­
ness has to be checked. 

The data as per point 3 and 4 will have to 
be taken into account with the use.

Applications other than described are not 
permitted without CCH / CEAG’s prior 
written consent. 

For the operation, the instructions stated in 
section 7 of the operating instructions will 
have to be observed.

In the open air, the plugs must be kept with the 
plug opening (pin side) pointing downwards or 
be closed with protective plug caps available as 
an optional extra (see general catalogue).

6 Installation

For the mounting and operation, the 

respective national regulations as well  

as the general rules of engineering will have 

to be observed.

6.1 Mounting

The wall sockets can be mounted without 
opening their enclosure.

In case the wall sockets are mounted directly 
onto the wall, they may rest evenly only at the 
respective fastening points. The chosen screw 
shall match the fastening hole (see dimensional 
drawing) and it must not damage the hole  
(e. g. use of a washer).

The device shall be fastened diagonally with at 
least 2 screws.

The wall sockets and flange sockets shall 
be mounted so  that the plug hole does not 
point upwards.

The wall sockets can be clipped onto the CCH / 
CEAG mounting plate size 4. They are laterally 
pushed into the guiding groove on the left-hand 
side of the mounting plate.

The respective mounting instructions will have 
to be observed.

6.2   Opening the device/ 

 

 

Electrical connection

The electrical connection of the device may  
only be carried out by skilled staff.

The insulation of the conductors shall 
reach up to the terminal. The conductor  
itself shall not be damaged.

Taking into account the respective regulations, 
the properly bared conductors of the cables 
shall be connected.

The electrical connection of the plugs is 
established as shown in fig. 4 and 5: 
The plug insert (item 2, fig. 5) is removed from 
the pin bushing (item 1, fig. 5), after the 
fastening screws (item 3, fig. 4) have been 
unscrewed. Thereafter, the plug insert can be 
connected to the connections of the plug pins 
(see view 1, fig. 5).

Attention: When the fastening screws 
(item 3, fig. 4) get lost, they will have to be 
replaced by similar screws or to be ordered 
directly from the manufacturer.

Assembly is made in inverse order, after the 
cable has been connected. 

The inlets are electrically connected as shown 
in fig. 6 to 8.

Fig. 6: After unscrewing the two screws item 3, 
the plug insert item 2 is removed from the 
flange item 2. 

Fig. 7: Now the connecting leads item 4 can be 
connected to the terminals of the plug insert 
item 2 as described in point 6.2. 

Fig. 8: Finally, using the self-cutting screws 
item 3, the plug insert item 2 is screwed into 
the flange, observing its proper position. 

The connectible min. and max. conductor 
cross-sections shall be observed  
(see technical data).

All screws and/or nuts of the supply terminals, 
also of those remaining vacant, shall be 
tightened down.

The supply terminals are designed for the 
connection of copper conductors. If multi- or 
fine-wire connecting cables are used, the wire 
ends will have to be handled in acc. with the 
applicable national and international rules  
(e.g. use of sleeves for strands).

Befestigungspunkt B 

Steckdose 16 A 4-pol.

 

 

 

              Item 3

 

 

      Item 3

 

  L1

  N

  PE

 

Item 2              Item1

 

     

 

Item 3

  Item 2

 

        View 1         View 2

            Item 2            Item 3        Item 1

  

 

Item 2        Item 1

  

 

                            Item 4

             Item 2     Item 1

Fig. 4

Fig. 5

Fig. 6

Fig. 7

Fig. 8

 

        

  B                     B

        

  B                     B

Plug and socket system for industrial use 16 A,  

3-pole, 4-pole, 5-pole, GHG 521

GB

Summary of Contents for GHG 521

Page 1: ...GHG 521 Plug and socket system for industrial use 16 A 3 pole 4 pole 5 pole GHG 521 Fiches et prises de 16 A 3 p les 4 p les 5 p les pour utilisation industrielle GHG 521 Betriebsanleitung Operating i...

Page 2: ...a 7 1 1 Plug and socket GHG 521 7 2 Safety instructions 8 3 Conformity with standards 8 4 Field of application 8 5 Application Properties 8 6 Installation 9 6 1 Mounting 9 6 2 Opening the device Elect...

Page 3: ...ignete Kombination aus Dichtungen so dass bei zuk nftigenWartungsarbeiten an der KLE die Hutmutter nachgezogen werden kann Stecker Kupplung 2 polig PE 8 18 mm Stecker Kupplung 3 polig PE 8 21 mm Steck...

Page 4: ...striellen Bereichen Sie sind nach IEC bis max 16 A einsetzbar siehe technische Daten Die Steckvorrichtungen sind generell f r den in der EN IEC 60309 festgelegten Spannungsbe reich einsetzbar z B UN 4...

Page 5: ...en Der Leiter selbst darf nicht besch digt sein Die ordnungsgem abisolierten Anschlusslei tungen der Kabel sind unter Ber cksichtigung einschl giger Vorschriften anzuschlie en Der elektrische Anschlus...

Page 6: ...f hren Au er dem ist vor der Inbetriebnahme die korrekte Funktion und Installation des Betriebsmittels in bereinstimmung mit dieser Betriebsanleitung und anderen anwendbaren Bestimmungen zu berpr fen...

Page 7: ...ination of seals in the intermediate area so that the cap nut can be tightened in future maintenance work on the cable entry Plug Coupler 2 pole PE 8 18 mm Plug Coupler 3 pole PE 8 21 mm Plug Coupler...

Page 8: ...see page 7 technical data The plugs and sockets can generally be used for the voltage range laid down in IEC EN 60309 e g UN 400V that corresponds to the voltage range 380 415V The apparatus connected...

Page 9: ...ach up to the terminal The conductor itself shall not be damaged Taking into account the respective regulations the properly bared conductors of the cables shall be connected The electrical connection...

Page 10: ...tioning and installation of the apparatus in accordance with these operating instructions and other applicable regulations will have to be checked Check the plug for any damages before putting it in t...

Page 11: ...l g rement selon le type de c ble et les propri t s des mat riaux utilis s Pour les plages de serrage interm diaires veuillez utiliser des garnitures d tanch it qui laisseront la possibilit de resserr...

Page 12: ...acement variable et d installations lectriques ainsi que de machines et de m canismes de commande mobiles en atmosph re industrielle Elles peuvent tre exploit es jusqu 16A au maxi selon CEI voir carac...

Page 13: ...nnel qualifi L isolation doit couvrir le conducteur jusqu la borne Le conducteur lui m me ne doit pas tre endommag En tenant compte des r glements respectifs les conducteurs d ment d nud s des c bles...

Page 14: ...e du mat riel les v rifications sp cifi es dans les r glements nationaux individuels devront tre ex cut es De plus il faudra v rifier son fonctionnement et installation corrects en conformit avec ce m...

Page 15: ...pler 3 pole Prolongateur 3 p les Kupplung 4 polig Coupler 4 pole Prolongateur 4 p les Kupplung 5 polig Coupler 5 pole Prolongateur 5 p les Ma Dimensions Dim A Wandsteckdose ohne Schalter 3 polig Wall...

Page 16: ...er Crouse Hinds CEAG estas instrucciones de servicio en otro idioma de la Union Europea EST Seda kasutusjuhendit oma riigikeeles v ite k sida oma riigis asuvast asjaomasest Cooper Crouse Hindsi CEAG e...

Reviews: