6. Appendices
6.3 Glossary
Bypass AC input
Bypass line from the AC power source, controlled by the UPS, used to directly supply the
load if an overload or a malfunction occurs on the UPS.
Backup time
Time during which the load can be supplied by the UPS operating on battery power.
Battery test
Internal UPS test to check battery status.
Equipments
Devices connected to the UPS output.
Excessive discharge
Battery discharge beyond the permissible limit, resulting in irreversible damage to the
battery.
FlexPDU
Module with UPS outlets for installation in a bay. There are different modules with dif-
ferent types of outlets.
Frequency converter
Operating mode used to convert the AC power frequency between the UPS input and
output (50 Hz -> 60 Hz or 60 Hz -> 50 Hz).
HotSwap MBP
UPS manual-bypass module for maintenance. There are different modules with differ-
ent types of outlets.
Low-battery warning
This is a battery-voltage level indicating that battery power is low and that the user
must take action in light of the imminent break in the supply of power to the load.
LCD
Liquid Crystal Display.
Normal AC input
The AC power line supplying the UPS under normal conditions.
Percent load
Ratio of the power effectively drawn by the load to the maximum output of the UPS.
Personalization
It is possible to modify certain UPS parameters set in the factory. Certain UPS functions
can also be modified by the
Personal Solution-Pac software
to better suit user needs.
Programmable
These outlets can be automatically shut down during operation on battery power
Outlets
(shutdown time delays can be programmed with the
Personal Solution Pac software)
.
The UPS has two sets of two programmable outlets.
Start on battery
The devices connected to the UPS can be started even if AC power is not available.
p
ower
The UPS operates on battery power alone.
UPS
Uninterruptible Power Supply.
UPS ON/OFF
This function enables or disables initiation of UPS ON/OFF control sequences by
Controlled by
computer pwower management software.
software
86-86710-00EN A02 - Page 31
86-86710-00 A02 UM.indd 31
14/01/2009 10:56:32
6.2 Programming the Programmable Outlets
1. To open the Setting window, left-click on Start Menu / Programs / EATON / Personal Solution Pac / Settings,
or right-click on the PSP power plug located in the SYS Tray.
2. Click on the “+” symbol next to “UPS Settings” to expand the “UPS Settings” section.
3. Click on “Startup Timer” and change the “The group of outlets restarts after” to “0” to have powershare outlet
provide power at the same time the as main outlets.
86-86710-00EN A02 - Page 28
6. Appendices
86-86710-00 A02 UM.indd 28
14/01/2009 10:56:32
Summary of Contents for EX Pulsar Series
Page 2: ...w P 86 86710 00...
Page 4: ......
Page 6: ......
Page 9: ...3 LED LED LED CFC HCFC UPS EATON EATON UPS EATON UPS...
Page 10: ...4...
Page 18: ...12 86 86710...
Page 22: ...16...
Page 33: ...www eaton com 86 86710 00 A02 86 86710 00 A02 UM indd 34 14 01 2009 10 56 53 www eaton com...
Page 34: ...w P 86 86710 00...
Page 36: ......
Page 38: ......
Page 42: ...4 86 86710 00...
Page 50: ...12 86 86710 00 This page left blank intentionally...
Page 54: ...16 4 4 4 86 86710 00 This page left blank intentionally...