Extended-Parameters
No.
Function
Unit
Step
Min
Max.
Code
Value
E08
Ramp selection
---
1
0
2
0 = digital set v.
(time constant)
1 = all set v. (rise
constant.)
2 = no function
1
E09
Time delay enable signal
s
0.001
0.000
+9.999
---
0.000
E10
Solenoid current adaptation
---
00.01
00.50
01.10
Variable adjustment
of max. current
01.00
E11
Initial current
V
0.001
0.000
+3.000
2.000
E12
Initial current
V
0.001
0.000
+3.000
3.000 V = 30 % of
max. rated current
2.000
E13
Dither Amplitude
V
0.001
0.000
+3.000
3.000 V = 30 % of
max. rated current
2.000
E14
Dither Frequency
Hz
0001
0001
0300
---
0130
E15
Select load/store
---
1
0
1
0 = Store into goal
1 = Load from goal
0
E16
Action load/store
---
1
0
1
0 = no action; 1 =
Start action
0
E17
Set value activation mode
---
1
off, 1
3
off = 4 digital, 3
analogue active
1 = 5 digital SP, 3
analogue active
2 = only 4 digital
active
3 = only 5 digital
active
Off
E18
Break output
---
1
off, 1
5
off = break off,
comp. Positive logic
1 = break on, comp.
Positive logic
2 = break follows
comparator
3 = break not and
comp. Positive logic
4 = break and comp.
Negative logic
5 = break not and
comp neg. logic
2
E19
Output factor analog output
---
00.01
00.00
02.00
---
01.00
E20
Swap feedback branch 1 /
branch 2
---
1
0
1
0 = Current
feedback addressed
to branch 1
1 = Current
feedback addressed
to branch 2
0
E21
Password
---
0001
0000
9999
To protect
parameters
Table 6: Extended Parameters – as delivered condition