Parameter for digital set values
No.
Function
Unit
Step
Min
Max
S1.01
Internal set value 1
V
0.001
0.000
+9.999
S1.02
Internal set value 2
V
0.001
0.000
+9.999
S1.03
Internal set value 3
V
0.001
0.000
+9.999
S1.04
Internal set value 4
V
0.001
0.000
+9.999
S1.08
Internal set value 8
V
0.001
0.000
+9.999
Table 7: Parameters for digital set values
Ramp parameters
Nr.
Function
Unit
Step
Min
Max
r1.01
Ramp from 0
⇒
–
s
0.001
0.000
39.50
r1.02
Ramp from –
⇒
0
s
0.001
0.000
39.50
r1.03
Ramp from 0
⇒
+
s
0.001
0.000
39.50
r1.04
Ramp from +
⇒
0
s
0.001
0.000
39.50
Table 8: Ramp parameters
Display parameters
#
Function
Unit
Step
Min
Max
d1.01
Sum of analog set value
V
0.001
-9.999
+9.999
d1.02
Sum of all post ramp set values
V
0.001
-9.999
+9.999
d1.03
Set values after linearization
V
0.001
-9.999
+9.999
d1.04
Value after gain adjustment.
V
0.001
-9.999
+9.999
d1.05
Signal A
---
0.001
-9.999
+9.999
d1.06
Signal B
---
0.001
-9.999
+9.999
d1.07
Current A
A
0.001
0.000
5.000
d1.08
Current B
A
0.001
0.000
5.000
d1.09
Total current
A
0.001
0.000
5.000
d1.10
Desired value
V
0.001
-9.999
+9.999
d1.11
Actual value, feedback value
V
0.001
-9.999
+9.999
d1.12
Lag error
V
0.001
-9.999
+9.999
d1.13
Controller output
V
0.001
-9.999
+9.999
Table 9: Display parameters
Commissioning
Non Warranty
This operating manual represents the knowledge of Eaton and during the drafting of this manual, the
greatest possible care was taken. Nevertheless, Eaton disclaims any responsibility and liability claims
for individual applications of the user. This is particularly true in cases of non-compliance, omissions,
faults, misinterpretations and misunderstandings.
Wiring
Card holder HC000000315303 has to be wired according to Fig. 7.
The supply voltage for the unit at terminals 26bd = 0V and 32bdz = +UB is 18 V to 32V DC, residual
ripple <10%.
Output stages are electronically protected against short circuit. The amplifiers should be protected with
a quick-acting preliminary fuse.