If the reset key is programmed to do an unlatch function only, the prompt message
will be UnL ?, and the acknowledge message will be UnL. If both reset and unlatch
functions are programmed, the prompt message will be r-U?, and the acknowledge
message will be r-U. If the reset key is programmed to do nothing, or if a batch is
running or recycling, pressing the reset key will result in a two-second display of six
dashes (------), which is the counter’s way of telling you, “I’ll just ignore that, thank
you.”
Alternate Between Two Count Factors
If CFACt appears while scrolling through the title screens, the counter is programmed
with two pre-loaded count factors and the operator may select the active count factor
via the front panel keys. The count factors are shown as CF1 and CF2, and the active
count factor appears on the display when the
View
Enter
key is released.
To change from CF1 to CF2, or vice versa,
1.
Press the
Edit
key,
Edit
PGM
D urant
The “1” will flash.
2.
Press the
or
Start
,
PGM
D urant
The flashing 1 becomes a flashing 2.
12345
12345
12345
12345
12345
12345
Indicates flashing digit.
12345
12345
12345
12345
12345
12345
Indicates flashing digit.
RUN MODE cont.