(totalizer, totalizer with relays, or batcher) and the functions necessary for the particu-
lar application (reset, unlatch, start, etc.), determine the function(s) of each control
input and select an input device appropriate to the function.
Relay Output
D urant
®
Term inal Designations
O u tpu t
2
O u tpu t
1
6
5
4
3
2
1
6
5
4
3
2
1
Ou tpu t
2
6
5
Ou tpu t
1
3
2
1
+
-
D ual R elay
R elay/Transisto r
Typical Wiring
L o a d
1
E x te rn a l
A C o r D C
P o w e r
+
-
L o a d
2
R elay
3
6
Tra nsistor
5
E x te rn a l
D C
P o w e r
Relay Contact Ratings
5 A @250 VAC or 30 VDC maximum
Transistor Ratings
OFF state: Block 30 VDC max, 0.1 mA max leakage current
ON state: Conduct 50 mA max, 1.2 V max C-E voltage drop
1
An RC surge suppressor is recommended across all inductive loads.
2
The transistor is optically isolated and may be connected as a sink (shown), or
a source by wiring the load between terminal 5 and - (minus).
3
A reverse-biased diode (1N 4001 or equiv.) is recommended across all
inductive loads.
General Wiring Practices
• Use shielded cables for signal and control inputs.
• Keep all signal lines as short as possible (<30M or 100 ft.).
• Do NOT bundle or route signal lines with power or machine control wiring.
• Do not allow signal or control wires to leave the building.
WIRING cont.