Putting into operation 

The time and date are set at the factory.   
The time switch is in Energy-saving 
mode.  Only the colon flashes.    
Press any key:  The time switch is activated 

Safety instruction: 

When operating the clock safety low voltage, only 

safety low voltage may be connected. 

When operating the clock with function low voltage, 

mains voltage (230 ~) or function low voltage may 
be connected.  The connection of safety low voltage 
is not admissible in this case. 

Connections 

Numbered terminals are located at the bottom of the 
time switch. These terminals have universal posi/slotted 
screws, accept up to 2 x 2.5mm

2

 cable and feature box 

clamps with cable protector plates. 
Connection details are: For the typical application where 
load and timer supply are common, the following      
connections are made: 

LOAD 

N.B. 
(a)

On large systems it is necessary to suppress the in-
terface voltage on contactor coils which are switched 
directly by the time switch using a suitable varistor or 
RC element. 

(b)

If inductive DC loads are switched, it is necessary to 
install a suppressor diode. 

(c)

Inductive loads, particularly fluorescent lamps, repre-
sent a particularly heavy strain for output   contacts. 
Here it is necessary to install an isolation relay or a 
contactor. 

Digital Quartz Timer                                                                    Product Code: AT2P 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for AT2P

Page 1: ...ails Dimension H x W x D mm 45 x 36 x 60 Distributor cut out mm 46 x 36 Weight g approx 170 Switching capacity at 230 V AC ohmic load VDE IEC 16A 250 V AC inductive load cos φ0 6 2 5 A 250 V AC glow lamp load 1000 W Switching contacts 1 or 2 changeover contacts Running accuracy 2 5s day at 200 C Running reserve type Lithium Running reserve 150 Shortest switching time 1 minute Programmable every mi...

Page 2: ...ave universal posi slotted screws accept up to 2 x 2 5mm2 cable and feature box clamps with cable protector plates Connection details are For the typical application where load and timer supply are common the following connections are made M 1 2 3 4 5 4 M 1 2 L N LOAD 3 5 N B a On large systems it is necessary to suppress the in terface voltage on contactor coils which are switched directly by the...

Page 3: ...Pulse cycle Continuous operation Manual operation The selections correspond to Central European Time The time switch offers 3 Operation modes The date and time and also the Operating mode AU are set Operating modes AU Automatic summer time controller switchover see 6 2 1 The switchover occurs on the dates defined by the legislator cHA Weekday related summer time controller switchover 6 2 2 You ent...

Page 4: ...ing settings Note You can exit conclude any adjustments changes you make at any time with the key 6 1 Time and day of the week Res Clear Prog 1 2 Day h m 1h 1 2 3 4 5 6 7 18 30 1h Press the key once Set the time With the h key hours With the m key minutes Note for weekly time switch If the Operating mode No no change see 6 2 3 Was selected the day of the week must now be set With the Day 1 Monday ...

Page 5: ... 5 6 7 19 98 Press the Prog key once Set the current year With the m key or the h key date Confirm with the Prog key Set the current month and day With the m key calendar month With the h key calendar day Note With the Prog key press once or twice read the date for the start e g 29 03 and end e g 25 10 Of summer time Res Clear Prog 1 2 Day h m 1h 1 2 3 4 5 6 7 Res Clear Prog 1 2 Day h m 1h 1 2 3 4...

Page 6: ...1 2 Day h m 1h 1 2 3 4 5 6 7 19 97 Press the Prog key once date Res Clear Prog 1 2 Day h m 1h 1 2 3 4 5 6 7 19 98 Set the current year With the m key or the h date Res Clear Prog 1 2 Day h m 1h Confirm with the Prog key Res Clear Prog 1 2 Day h m 1h 1 2 3 4 5 6 7 14 10 Set the current month and day With the m key calendar month With the h key calendar day date Digital Quartz Timer Product Code AT2...

Page 7: ... Res Clear Prog 1 2 Day h m 1h 1 2 3 4 5 6 7 30 04 date Res Clear Prog 1 2 Day h m 1h 1 2 3 4 5 6 7 25 10 Confirm with the Prog key date Res Clear Prog 1 2 Day h m 1h 1 2 3 4 5 6 7 27 10 Set individual summer time end With the m key month With the h key day date Res Clear Prog 1 2 Day h m 1h CH1 1 2 3 4 5 6 7 18 35 Press the key once The input is ended 1h Digital Quartz Timer Product Code AT2P ...

Page 8: ...dard switching commands You determine the switching times and the switching state of the relevant switching output channel Symbol CH1 CH2 y ON Channel 1 OFF Channel 2 These assignments are possible Switching commands only for channel 1 Switching commands only for channel 2 The same switching commands for channel 1 and channel 2 the switching time and switching state are identical The same switchin...

Page 9: ...The input has ended A free memory location is displayed for other settings CH1 CH2 Res Clear Prog 1 2 Day h m 1h 1 2 3 4 5 6 7 18 40 1h y Press the key once The input is ended The display shows the current time 8 Fixed weekday block formation only weekly time switch Defined combinations of weekdays or individual days You determine the weekdays for your switching program 1 Monday 2 Tuesday 3 Wednes...

Page 10: ...s see 7 y ON OFF 1 2 3 4 5 6 7 Res Clear Prog 1 2 Day h m 1h Press the Prog key once The input is ended A free memory location is displayed for further settings CH1 Res Clear Prog 1 2 Day h m 1h 1 2 3 4 5 6 7 18 00 1h y Press the key 1 once The input is ended The display shows the current time Note After the procedures Read modify or delete the time date switching program DCF synchronisation Resto...

Page 11: ...g command contents which you want to change overtype Change the switching command contents As described in 8 Weekday block formation Delete individual switching commands Press the Prog key step by step as far as the switching command contents which you want to delete Press the Clear key once This switching command is deleted Res Clear Prog 1 2 Day h m 1h CH1 CH2 00 00 1 2 3 4 5 6 7 Fr 28 1 2 3 4 5...

Page 12: ...nd switch You change manually the current switching state However the individually set switching program is preserved 1 for channel 1 2 for channel 2 automatic Manual mode FIX continuous operation OFF ON The switching state corresponds to the entered program y ON OFF You change m a n u a l l y The current switching state The next switching command in the program is executed automatically again y F...

Reviews: