Environmental tests
Test
Standard & Test class
Test value
Dry Heat Operational
EN 60068-2-2:2007, Test Be
70°C, 16h, On
Dry Heat Storage
EN 60068-2-2:2007, Test Bb
70°C, 16h, Off
Cold Test Operational
EN60068-2-1:2007, Test Ae
-40°C, 16h, On
Cold Storage
EN60068-2-1:2007, Test Ab
-40°C, 16h, Off
Damp Heat
EN60068-2-78:2013, Test Cab
40°C, 10d, Off, 93%RH
Cycling Temperature with Humidity EN60068-2-30:2005, Test Db
25°C/40°C, 6d, Off, 93-97%RH
Change of Temperature
EN60068-2-14:2009, Test Nb
-40°C/+70°C, 50h, Off
Table 5 .4: Environmental tests
Environmental conditions
Specified ambient service temperature range
-40…+70°C
Transport and storage temperature range
-40…+70°C
Relative humidity
Up to 95%
Table 5 .5: Environmental conditions