20
INM 9476-ETG Rev 2
23
LOGOUT OF CURRENT WEB SESSION
This page logs the current user out of the web session.
It is highly recommended that once finished using the web interface that you log out
enforcing that the password will have to be entered next time the unit is accessed.
24
RESET BUTTON
There is a hardware push button that is accessible through the small hole in the front
panel, near to the LEDs. This may be needed for example if the password is unknown
and you need to factory default the unit to again allow access to configure it.
The button has two functions depending on when it is pressed -
1 . Press on power-up
= This puts the unit into
Bootloader Mode
, ready for a firmware
upgrade. The watchdog LED
flashes red
and the status LED turns
red
also. To exit this
mode cycle the power to the unit.
2. Press 1-2 seconds after power-up = Factory Default Mode. This temporarily sets the
unit to the defaults described in this manual (IP Address 192.168.0.200, HTTPS etc.).
The watchdog LED
flashes green
and the status LED is
red
. The user can then access
the webpage at the default IP address (https://192.168.0.200) make any changes to
the configuration and save them. If the user cycles power before saving any settings
then the unit reverts back to the previously saved settings.