background image

 

15 

 

Gates remain 
open after 
systems 
learn/one arm 
stays open 
and the other 
one closed. 

-

 

Ensure you have matched the + and - of 
each ram to the equi and – motor 
symbols on the board. 

-

 

Clear any obstructions to the gates. 

-

 

Make sure that the rams are going no 
further than 100 degrees. 

-

 

The dip switch setting should be set for a 
double swing and not a single. 

-

 

If LED 1 is a solid red hold systems learn 
until it flashes. Then press the remote top 
left hand button once. 

-

 

Ensure the motors are locked in. 

-

 

Increase the power amp settings by 
following the dip switch settings (mentioned 
above). 

 

Gates not fully 
opening or 
closing 

-

 

Ensure there is nothing obstructing the gate 
or the rams. 

-

 

If the gate is a bigger or heavier gate 
change the power settings using the 
dipswitches (1

st

 set of dip switches). You 

should not have to use the maximum power 
setting. This is intended for a 500kg double 
swing gate (or 250kg single). 

-

 

Re-do the systems learn. 

 

One gate 
opens part of 
the way/not 
at all. 

-

 

Make sure you are pressing the top left 
hand button. The other buttons do have 
their individual functions. 

-

 

Dip Switch 7 setting has been set correctly. 

-

 

Both rams are wired onto the control board 
correctly. They should identical. I.E. black, 
red. Black, red. 

 

Single gate 
LED 1 stays 
on. 

-

 

Dip switches 1 and 2 on bank 3 are ON 

-

 

Dip Switch 7 on bank 1 is OFF 

-

 

Battery clip is connected. 

-

 

The motor is connected to MO1 and not 
MO2 

-

 

Press and hold SYS-LEARN for 3 seconds 
until LED1 starts flashing again. 

-

 

Press the remote once and wait until it 
starts moving. This can take up to 5 
seconds. Do NOT obstruct the learning 
process. The gate will open and close 
several times. 

 

Remote/ 
keypad range 
is less than 
20M 

-

 

Make sure the antenna is attached and 
screwed in on the control board. 

-

 

Make sure there is nothing obstructing the 
antenna such as the power cable or motor 
cables. 

 

 

EasyGate Warranty Terms and Conditions

 

PLEASE READ THE FOLLOWING TERMS AND CONDITIONS OF USE CAREFULLY. 

Warranty: This is a “Back to Base Warranty”

 

Summary of Contents for Terrier 200

Page 1: ...1 Installation Guide by EasyGate for Terrier Swing Gate System...

Page 2: ...r arms 2 x arm mounting brackets 1 x gate bracket cylinder pins with grub screw 1 x post bracket bolts and nuts 1 x arm unlocking keys 1 x control box 2 x batteries fitted under control board 1 x cont...

Page 3: ...3 Post bracket pin and wear bush location in tongue plate hole Arm to Gate bracket with pin and crub screw Key to assist opening clutch lever Fully Open ram retracted Fully Closed ram extended...

Page 4: ...round The gates must be able to open and close freely without swinging into the control box Wiring Double Gate Arms to control box To protect the cable place into PVC pipe or in concrete driveways pla...

Page 5: ...also buy this with the optional transformer built into the control box Calculate how much 2 core cable you will need to run out from the power source to the gate It should be a min of 1 5mm core diame...

Page 6: ...e battery terminal and the AC transformer You should now see LED no 1 flash red 2 flash bursts every second a Press the RF learn button in the top left hand corner for 3 seconds until the blue light g...

Page 7: ...rn has finished LED no 1 should be revert back to flashing in bursts You have successfully set up your gate opener kit and is now ready for testing Pedestrian mode To open a gate for a pedestrian simp...

Page 8: ...top Switches 1 1 on The gates WILL NOT slow down before the gates completely close or open 1 off The gates WILL slow down before the gates completely close or open Current adjustment This function is...

Page 9: ...ing The following functions are all on SW2 middle block of switches SW2 Close and open delay This is the delay between activating your remote keypad and for the gates to start moving Switches 3 and 4...

Page 10: ...operation 2 on Option 3 1 off Button C for single gate operation Button D for double gate operation 2 on Option 4 1 off Button C for double gate operation Button D for single gate operation 2 off Swi...

Page 11: ...ouble terminal 7 Installing wired Button to Double gates Connect Com of the button to G on terminal 9 and D short for double terminal 7 Also used for intercom or dial to open Installing wired keypad t...

Page 12: ...he white from the other Take the remaining white and green wires from opposite probes and twist these together so it is in series If installing WITH safety beams From the EMX VMD202 R Probe Positive r...

Page 13: ...control board is wired correctly At the control board check both battery and transformer white connector blocks are correctly plugged into board Check fuses are both working 15amp for stand alone tra...

Page 14: ...the keypad Do this by flicking off the front cover with a small screw driver Undo the 2 nuts turn over and repeat until left with the control board on the casing Undo the 3 screws in the corner Turn...

Page 15: ...ate or 250kg single Re do the systems learn One gate opens part of the way not at all Make sure you are pressing the top left hand button The other buttons do have their individual functions Dip Switc...

Page 16: ...ping or handling Installation or removal of product Damage caused by natural or manmade disaster such as fire flood wind earthquake or lightning etc Damage due to causes beyond the control of EasyGate...

Page 17: ...the attention of the users of this system System Failures This system has been carefully designed to be as effective as possible There are circumstances however involving fire burglary or other types...

Page 18: ...rference Component Failure Although every effort has been made to make this system as reliable as possible the system may fail to function as intended due to the failure of a component Inadequate Test...

Reviews: