10
The following functions are all on
SW3
(bottom block of switches).
Switches: 1 and 2
This function is to select the command button of the remote
Option 1 (default setting for double gate)
1 on
Button A for double gate operation
Button B for single gate operation
2 off
Option 2 (setting for single gate)
1 on
Button A for single gate operation
Button B for double gate operation
2 on
Option 3
1 off
Button C for single gate operation
Button D for double gate operation
2 on
Option 4
1 off
Button C for double gate operation
Button D for single gate operation
2 off
Switches: 3 and 4
This function is to activate the photo beam
3 on
4 on
Default setting for no photo beam installed
3 on
4 off
FO1 is connected ; FO2 no photo beam installed
3 off
4 on
FO1 no photo beam installed ; FO2 is connected
3 off
4 off
FO1 and FO2 both are connected, 2 sets of photo beam
Important
: If the photo beam has been removed, switches must turn back to ON