60
Vertical
Measure
The program Vertical uses the 9-12-3 method.
1. Position the units at 9 o’clock, at bolt number one. Make sure that it is possible to
also position the units at 12 and 3 o’clock.
2. Press
to register first position. The first position is automatically set to zero.
3. Turn units to position 12 o’clock.
4. Press to register position.
5. Turn units to position 3 o’clock.
6. Press to register position. Measurement result is displayed.
Circle indicates where
to position the S-unit.
Edge warning
Edge warning
When the laser beam is close to the edge, the edge is “lit up” as a warning. It is not
possible to register values when you see the edge warning.
The measuring units at 12 o’clock. Arrows
indicates live values.
Offset
Angle