ADJUSTMENTS AND REPLACEMENTS
40
01JUN99 – 5B6331
Removing the IMPELLER HOUSING or the IMPELLER
Important
Use this procedure for either the developer IMPELLER
HOUSING or the fixer IMPELLER HOUSING.
[1] Remove the RECIRCULATION PUMP.
[2] Remove the 4 WING NUTS from the IMPELLER
HOUSING.
[3] Remove the IMPELLER HOUSING from the
RECIRCULATION PUMP.
Caution
To prevent chemical contamination, do not interchange
the developer and fixer IMPELLERS or the developer
and fixer IMPELLER HOUSINGS.
[4] Remove:
• SCREW
• WASHER
• IMPELLER
[5] Check the O-RING for wear. If necessary, install a
new O-RING.
[6] To prevent leakage, check that the O-RING is
correctly seated.
[7] Install the new parts and assemble the
PROCESSOR.
H150_0165AA
H150_0165ACA
NUTS
4 WING
O-RING
IMPELLER HOUSING
IMPELLER
WASHER
SCREW