DIAGNOSTICS
6
30SEP98 – 5B6333
E014
Invalid program software
E014 is displayed on the DEVELOPER TEMPERATURE DISPLAY. This
error disables all subsystems, except communications.
The main program software in the
EEPROM on the 5000 BOARD
Download new software.
E015
Invalid bootstrap software
The bootstrap software for the
PROM U5006 on the 5000 BOARD
Install a new U5006.
E016
Invalid film accumulator
software
This error does not disable any subsystems. The PROCESSOR will remain
in the standby mode until the FILM DETECTOR SWITCHES actuate. These
SWITCHES provide information about the length of the film. Because the
6000 BOARD does not operate correctly, the PROCESSOR uses the
information from the SWITCHES to determine the replenishment rate.
The main program software in the
EEPROM on the 6000 BOARD
Download new software.
Code
Description
Possible Malfunction
Action