INSTALLATION INSTRUCTIONS
8
15JUN98 – 9B8948
Section 5: PROCESSOR Voltage
Checking and setting the PROCESSOR voltage
If the PROCESSOR is a 1000A or 1000J, advance to Installing the PROCESSOR on
.
If the PROCESSOR is a 1000, you must check the internal voltage setup and change the voltage setup if necessary:
[1] Open the PROCESSOR:
(a) Remove the 2 SCREWS on top of the feed
end of the PROCESSOR.
(b) Remove the SCREW from the DEVELOPER
and FIXER DRAIN VALVE BRACKET.
(c) Remove the SCREWS from the WASH
WATER OVERFLOW and WASH WATER
DRAIN FITTINGS under the front of the
PROCESSOR.
Warning
The top of the PROCESSOR does not automatically
remain up. You must hold the top of the PROCESSOR
up or it will fall.
(d) Slowly open the top of the PROCESSOR.
There is a HINGE at the dryer end.
Note
The HOSES might prevent you from opening the
PROCESSOR. Feed the HOSES into the
PROCESSOR as you open it.
H164_0076AC
DRAIN FITTINGS
OVERFLOW and
WASH WATER
DRAIN VALVE BRACKET
DEVELOPER/FIXER
PROCESSOR
2 SCREWS
H164_0076ACA