INSTALLATION INSTRUCTIONS
18
15JUN98 – 9B8948
Setting the DRYER Temperature
[1] Use the following table to select and set the DRYER temperature. Count the increments between the “LOW”
and “HIGH” positions.
DRYER Temperature
Final Pre-Operation Checks
[1] Use the OPERATOR MANUAL to complete the setup of the PROCESSOR:
(a) Mix the developer and fixer solutions.
(b) Do the Procedure “Filling the Tanks in the PROCESSOR”.
[2] Process test films to check the operation of the PROCESSOR.
Position
Temperature
Positio
n
Temperature
LOW
35
°
C (95
°
F)
8
51
°
C (124
°
F)
1
37
°
C (99
°
F)
9
53
°
C (127
°
F)
2
39
°
C (102
°
F)
10
55
°
C (131
°
F)
3
41
°
C (106
°
F)
11
57
°
C (135
°
F)
4
43
°
C (109
°
F)
12
59
°
C (138
°
F)
5
45
°
C (113
°
F)
13
61
°
C (142
°
F)
6
47
°
C (117
°
F)
14
63
°
C (145
°
F)
7
49
°
C (120
°
F)
HIGH
65
°
C (149
°
F)
H164_0037AC
High
Low
Dryer Temperature