background image

Appendix A: Electrical Schematic   57 

 

Appendix A: Electrical Schematic 

 

 

 

Summary of Contents for SB-2EX-Auto

Page 1: ...SB 2 3EX Auto Automatic Case Taping System User Guide...

Page 2: ......

Page 3: ...B Copyright and Trademarks Copyright 2012 2022 Engage Technologies Corporation All rights reserved All trademarks and brand names are the property of their respective owners Eastey 7041 Boone Ave N B...

Page 4: ......

Page 5: ...tch Operation 24 Control Panel Operation 24 Adjustments 26 Air Pressure unit 26 Height and Width Adjustment 27 Top Squeezer Roller Width Adjustment 28 Flap Closing Guide Adjustment 28 Rear Flap Closer...

Page 6: ...Infeed Index Roller Table 53 Options 55 Appendix A Electrical Schematic 57 Warranty Statement 63 Customer Support 65...

Page 7: ...not place hands near the belts when they are moving as fingers may be pinched where belts enter the frame We suggest the use of a roller type exit conveyor or pack table for your cases Always remove...

Page 8: ...damage to equipment or nearby property Electrical hazard Indicates caution electrical shock hazard Allow only a trained electrician to open the door or cover of the electrical panel or box Shut off e...

Page 9: ...ty glasses when operating or servicing this machine Refer to this User Guide for important safety information and operating instructions to set up operate adjust and maintain this Automatic Case Erect...

Page 10: ...es Crank handles for height and width adjustments are removable and can be used on either side of the machine Rear Flap Folding Kicker Height Adjustment Crank Width Adjustment Crank Control Panel with...

Page 11: ...hangeable with top and bottom cartridges Air Requirements 85 PSI Electrical Requirements 110 VAC 60Hz 4 0A Agency Approvals CE Certification SB 2 3 AUTO Case Taper Standard Features Utilizes Eastey s...

Page 12: ...ine This case taping machine is intended for operation to automatically close top flaps and seal top and bottom flaps of cases by applying OPP oriented polypropylene tape Do NOT use the Automatic Case...

Page 13: ...ble Adjustable Height 71 12 in 190 8 cm Machine Body Indexing Table Width 89 15 in 236 6 cm Machine Infeed Indexing Table Overall Length Optional For optional light stack add 12 2 in 30 99 cm to Top o...

Page 14: ...lled onto the four adjustable support legs To install casters thread one caster into the bottom of each leg CAUTION Raise the case taper off the floor to install the casters Use proper equipment when...

Page 15: ...location you will need access to 1 The Main Power Switch and Control Panel with Start Run and Stop buttons and E Stop 2 Height and width adjustments 3 Both upper and lower tape cartridges for tape lo...

Page 16: ...16 Installation Air Supply Line In Air In...

Page 17: ...d table so rollers are level with the case taper rollers 3 Re tighten cap screws loosened in the first step to secure table Next Steps Follow instructions in the Operation section for instructions to...

Page 18: ...remove the tape cartridge before loading tape When handling the tape cartridge be careful to avoid contact with the tape cutting blade After the taping cartridge has been removed push the tape roll on...

Page 19: ...hrough the rollers in the tape head as shown in the applicable diagram in the Tape Head User Guide provided with the tape head For convenience diagrams for threading tape in the Eastey EX Tape Head an...

Page 20: ...20 Operation Eastey EX Tape Head EZ EX Tape Head Adhesive Side Adhesive Side Adhesive Side Upper Cartridge Bottom Cartridge Adhesive Side Upper Cartridge Bottom Cartridge...

Page 21: ...and bottom seams when applying tape than partially filled cases where excessive pressure could possibly crush the case For sealing light weight boxes decrease the main spring tension For heavier boxe...

Page 22: ...main spring is hooked onto Eastey EX Main Spring Adjustment For the EZ EX tape head there are two adjustment nuts one to each side of the top crossmember where the threaded rod of the adjustable end...

Page 23: ...se taper The main power switch is located on the door of the electrical panel The power indicator light is located above the main power switch The control panel is located on the same side of the mach...

Page 24: ...ower indicator lamp will be illuminated Control Panel Operation Press Start button on the control panel to begin automatic taper operation Power Indicator Lamp White On when case taper is in operation...

Page 25: ...rgency Stop button for emergency stop To reset the Emergency Stop button once the emergency condition has been cleared and it is safe to operate the machine again press the Emergency Stop button in wh...

Page 26: ...The air pressure can be changed up or down for specific requirements Make air pressure setting changes only in small increments Inspect the unit periodically to make sure the drain system is function...

Page 27: ...t width to the correct box width Use the height adjustment crank to set the upper tape head to the correct box height The height and width cranks can be mounted on either side of the machine by loosen...

Page 28: ...box width and re tighten the locking knobs This will ensure the box stays centered Flap Closing Guide Adjustment When front cardboard flap touches the front flap folder the front flap will be folded t...

Page 29: ...rms are moveable and adjustable in both the height and width axes Rear Flap Closer Speed Adjustment NOTE Flow controls for extension and retraction of the rear flap closer are pre set at the factory a...

Page 30: ...allow increased airflow Belt Adjustment It is not necessary to remove the drive belt cover to adjust the drive belt To adjust the belt use an allen wrench and loosen the socket head cap screw that lo...

Page 31: ...closer kicker The drop conveyor gating infeed roller table ensures that only one case enters the auto case taper at a time and prevents any subsequent case from entering the flap closing area of the...

Page 32: ...rd into the flap folding area while the current case is being processed The case will move into the area of the second photo eye sensor B Where sensor A is activated by the case blocking the sensor se...

Page 33: ...ed roller table to rise back up level with the rollers and it signals for the rear top flap closer to swing back up to its home position and the Auto Case Taper is ready for the next case Roller Index...

Page 34: ...been transported onto the main taper rollers and the trailing 1 3 of the case length is remaining on the indexing table Roller Indexing Table raises back up to home position C Rear top flap closer swi...

Page 35: ...leg height CAUTION Ensure the case taper is secure and will not shift while adjusting leg height Tape Head Adjustment Refer to Tape Head User Guide Refer to instructions in the Tape Head User Guide th...

Page 36: ...cal agents when cleaning the rollers Cutting Knives Occasionally inspect the cutting knives to ensure they are clean and free of adhesive residue Make sure the cutting knife is sharp by inspecting cut...

Page 37: ...d or exit photo eyes sensors a Re position hoses wiring b Adjust the position of photo eye or replace with a new one If the machine cannot tape boxes The side belts are not correctly adjusted for the...

Page 38: ...38 Parts Lists Parts List Electrical 1 19 24 25 30 31 32 Optional Optional...

Page 39: ...Parts Lists 39...

Page 40: ...5507 THERMAL OVERLOAD RELAY LR3D06 1 1 6A 400V 50HZ P0306 040000400 1 13 5005508 TERMINAL POST 30P P0304 010007300 1 15 5001874 ON OFF SWITCH BOX XALD04 71840002 1 16 5001824 AUTO RUN GREEN LAMP COVER...

Page 41: ...T TOWER option KA0000410 1 31 1 5005398 ILLUMINATED units XVMC33 Green option KA0200050 1 31 2 5005399 ILLUMINATED units XVMC34 Red option KA0200060 1 31 3 5005400 ILLUMINATED units XVMC35 Orange opti...

Page 42: ...9 5005284 1 8 SLEEVE 81150002 2 10 5005515 CONNECTOR PE8 P0401 0007100 1 11 5002100 CONNECTOR JSC8 01A 81060127 2 12 5005516 ISO CYLINDER MCQV2 11 40 100 P0402 0001400 1 13 5005517 ISO CYLINDER MCJQ...

Page 43: ...Parts Lists 43 Side Belts...

Page 44: ...50 MOTOR 240V 50HZ T15 1 745124L2 1 10 5001714 V3 50 MOTOR 380V 50HZ T15 1 745138L1 1 10 5005290 MOTOR 400V 50HZ T15 1 745140L1 1 11 5005525 RING S 14 P1105 0114B 36 12 5005526 PULLEY SHAFT P02 00796...

Page 45: ...OR 110V 60HZ T18 1 745111R1 1 35 5001713 V1 60 MOTOR 220V 60HZ T18 1 745122R1 1 35 5001713 V1 60 MOTOR 220V 50HZ T15 1 745122R2 1 35 5001713 V2 50 MOTOR 240V 50HZ T15 1 745124R2 1 35 5001713 V3 50 MOT...

Page 46: ...46 Parts Lists Vertical Column with Height Adjustment...

Page 47: ...11 5001850 COLUMN SCREW RIGHT P02 007370A 1 11 5001851 COLUMN SCREW LEFT P02 007380A 1 12 5005562 FIX SEAT P01 0125900 2 13 5030971 BEARING 6202ZZ CWB P1104 026202ZZ0 2 14 5005563 COLUMN BEARING SEAT...

Page 48: ...CRIPTION REFERENCE Q TY 27 5005569 TRANSMISSION SHAFT P02 0074000 1 28 5005570 COVER FRAME TOP 1 29 5005571 BEARING 6002ZZ NR CWB P1104 076002ZZ0 2 30 5005572 FIX SEAT 1 31 5005573 C RINGS 15 P1105 01...

Page 49: ...Parts Lists 49 Flap Guide and Upper Tape Head Seat Assembly ITEM PART NO DESCRIPTION REFERENCE Q TY 1 5005576 SUPPORT BAR P02 0074400 2 2 5005577 FOLDING DEVICE SEAT 1 3 5005578 SUPPORT PLATE 1...

Page 50: ...CKING BRACKET 2 17 5005592 HANDLE KNOB M10x63 P1113 0003900 2 18 5005593 CONNECT SEAT 1 19 5005594 FOLDING DEVICE SEAT 1 20 5005595 FOLDING DEVICE BRACKET 1 21 5005596 FIXED HANDEL P1112 0000400 4 22...

Page 51: ...Parts Lists 51 Machine Body...

Page 52: ...005616 NUTN 1 2 P1102 01B4AZ 4 8 5001912 CASTER P1107 0000300 4 9 5005617 CONTROL BOX 1 10 5005618 WIRING PLATE 1 11 5005619 CONTROL BOX DOOR 1 12 5005620 ROLLER LONG P08 0005000 22 13 5005621 ROLLER...

Page 53: ...Parts Lists 53 Infeed Index Roller Table...

Page 54: ...7 CYLINDER FIX PLATE 1 7 5005658 PIVOT SHAFT P02 0363500 1 8 5005659 FRAME P01 0615500 1 9 5005660 BEARING P1104 076201ZZ0 2 10 5005661 CYLINDER SEAT P02 0394800 1 11 5005662 BUSHING P1104 0312060 2 1...

Page 55: ...Parts Lists 55 Options...

Page 56: ...O EYE SENSOR P0302 020000600 4 11 5005636 PHOTO EYE SENSOR SUPPORT INNER 1 12 5005637 PHOTO EYE SENSOR SUPPORT OUTTER 1 13 5005638 ALARM LIGHT SET P0312 010001900 1 14 5005639 ALARM LIGHT SEAT 1 15 50...

Page 57: ...Appendix A Electrical Schematic 57 Appendix A Electrical Schematic...

Page 58: ...58 Appendix A Electrical Schematic Electrical Schematic Continued...

Page 59: ...Appendix A Electrical Schematic 59 Electrical Schematic Continued...

Page 60: ...60 Appendix A Electrical Schematic Electrical Schematic Continued...

Page 61: ...Appendix A Electrical Schematic 61 Electrical Schematic Continued...

Page 62: ...62 Appendix A Electrical Schematic Electrical Schematic Continued...

Page 63: ...n an application will be the same as that achieved on a test piece in our laboratory Shipping Policy Customer pays all incoming shipping If the item is defective and under warranty Eastey pays return...

Page 64: ...ULAR PURPOSE AND NONINFRINGEMENT Disclaimer of Damages REGARDLESS OF WHETHER ANY REMEDY SET FORTH HEREIN FAILS OF ITS ESSENTIAL PURPOSE IN NO EVENT WILL EASTEY BE LIABLE FOR ANY SPECIAL CONSEQUENTIAL...

Page 65: ...UTO Automatic Case Taper please contact Eastey Technical Service at one of the numbers listed below Toll Free Phone 800 835 9344 Phone 763 428 4846 Fax 763 795 8867 E mail info eastey com Web www east...

Page 66: ......

Page 67: ......

Reviews: