Static
Calibration
(Static
Cal.)
Static
Calibration
sets
the
Range
of
the
Transducer
in
the
CentriFlow
Meter.
This
allows
the
meter
to
be
versatile
in
a
way
such
that
it
can
be
ranged
up,
known
as
Extended
Static
Calibra
‐
tion,
or
it
can
be
ranged
down,
known
as
Reduced
Static
Calibration.
The
Static
Calibration
is
a
Factory
Setting
and
should
not
need
to
be
changed
while
the
meter
is
in
service,
unless
the
Transducer
has
been
replaced.
Setting
or
checking
the
Static
Calibration
consists
of
two
steps
–
Zero
and
Static
Calibration.
Note
that
readings
are
measured
using
two
different
units
‐
%PV
and
%
Volts.
The
difference
between
the
two
scales
is
the
Dynamic
CAL
multiplier.
The
nomi
‐
nal
value
is
five
(5),
this
value
equates
to
multiplying
by
one.
Before
beginning
the
calibrations,
make
sure
that
there
is
no
product
on
the
Pan
or
around
the
Pan
Arms.
The
procedure
for
setting
or
checking
the
Static
Calibration
is
as
follows:
Step
1:
Click
the
CAL
Button
on
the
TOP
Menu,
then
click
the
ZERO
Button.
Step
2:
You
should
now
be
on
the
CAL.ZERO
page
as
seen
below.
Step
3:
Press
the
Zero
Button.
Verify
that
the
number
displayed
in
the
Diagnostic
Window
is
0.0
%
Process
Variable.
Step
4:
The
Zero
portion
of
Static
Calibration
is
complete.
Press
the
Red
TO
CAL
Button
on
the
upper
right
of
the
screen
in
order
to
return
to
the
TOP.CAL
page.
Step
5:
Press
the
CALs
Button.
You
should
now
be
on
the
CAL.CALs
page
as
seen
on
the
next
page.