Ultra Compact Meter Controlled Water Softener
Setting the machine to service
Complete the programme sections before setting into service
mode (see page 5 of this guide).
To set the machine to service simply alter the position of the
inlet and outlet valve and turn the bypass valve to the off
position. It is recommended that this procedure is completed in
the following order.
1.
Turn the softener inlet valve to the on position
2.
Turn the bypass valve to the off position. Allow
approximately five minutes to let the incoming water to
build a level of pressure before completing step 3.
3.
Turn the softener outlet valve to the on position.
You should now complete any programming instructions that
apply to your particular machine and perform a manual
regeneration.
5
A manual regeneration is performed at this stage to allow you to confirm that the unit has no
leaks from the installed valves and the waste runs free. This regeneration will also assist in
clearing any potential air locks that may be present within the system. The regeneration will
also reset any internal meter or timer devices that dictate the frequency of the regeneration
cycle.
It is important that you have your softener regularly serviced. We recommend that your
softener is serviced every 24
-
36 months. Like a car, your softener needs to be checked over
to ensure it is working at its optimum performance levels.
Your machine should now be supplying your property with soft water. If you find that the
water feels too soft for you it is possible to dilute the softness by slightly opening the bypass
valve and allow some hard water to blend
If is important that the softener is sited in a position where the controls cannot be inadvertently
altered or changed accidentally as there is no lock out facility on this water softener.