Planning your installation

 

Always observe the water bylaws. Ensure there is only one rising main and that you have allowed space for 
access to the unit for salt filling and possible maintenance in the future. 

 

Check the water pressure; locate the rising main (stop cock), a drain facility and a power supply. We 
recommend installation by a competent handyman or a qualified plumber. 

If you have difficult or non 

standard pipework, we suggest you consult a qualified plumber for advice, before commencing 
installation.  

Ensure you have all the necessary connections and valves before you start work. It is important 

that you fit a bypass valve so that the softener can be isolated if required.  Valves, installation kits and wire 
clamps are not included with this softener. Please check all packaging for any parts and check your 

Siting the softener

 

This should be as close to the rising main as possible. Allow hard water take 
off points for a drinking water facility and /or an outside tap if required. For 
easy DIY installation we recommend the fitting of a hard or filter water kit.  If 
the stopcock is located in a difficult position to create a hard water supply, you 
can fit a Reverse Osmosis system. The distance between the drain and the 
softener should be as short as possible. Ensure that both the drain and 
overflow are not subject to excessive temperatures (freezing or over 120°F).  If 
you are siting the softener in a cupboard, ensure that the base of the cupboard 
is adequately supported. If the softener is being installed in a loft, it is 
recommended that you house the softener within a well insulated 25

-

gallon 

tank. The overflow on the tank should be below the softener overflow and be a 
minimum of ¾

” 

in size. 

 

 

Non Return Valve

 

In single dwellings, a non return valve should be fitted. This is supplied with 
our 15mm installation kits  and can be ordered separately. 

 

Check list 

 

If you purchased an EMWC fitting kit with your softener, all valves required for 
installation will be included. Combi boilers require a 

Combi Kit. 

Pressurised 

systems require a 

22mm Fitting Kit. 

Check you have ordered the correct fitting 

kit for your installation. 

 

Water Pressure Test

 

It is important that you carry out a pressure test. High and low water pressure 
can result in damage to/failure of the softener. Although the softener is tested 
to a pressure of 8 bar we recommend the fitting of a pressure limiter should 
your pressure exceed 5 bar (70 psi). We also recommend that any household 
appliance using water should be fitted with a leak controller.

 

 

Typical Softener Installation 

Valve Configuration

 

IMPORTANT INFORMATION:  

Before starting the installation of the valves, ensure THE STOP COCK IS IN A CLOSED position.

 

DO NOT ADJUST THE RED BAR ON THE SOFTENER—THIS IS ONLY TO BE USED BY OUR ENGINEERS

 

3

 

Summary of Contents for Ultra Compact

Page 1: ...INSTRUCTIONS BEFORE INSTALLATION IF YOU PURCHASED A 15mm or 22mm FITTING KIT THESE ARE PACKED INSIDE YOUR SOFTENER Contents of box Your EMWC Ultra Compact water softener 1 2 flexible hose for the overflow Instructions for installation Your warranty details are stored digitally transformer Plus a fitting kit if purchased CHECK INSIDE YOUR SOFTENER AS THIS IS WHERE IT WILL BE PACKED Blue 3 8 waste h...

Page 2: ...cess water is drawn from the brine tank and flushed through the system At the end of the cycle water is put back into the brine tank in order for the salt to dissolve ready for the next time the machine needs to regenerate On some units this is delayed until a few hours before regeneration The level of water in the tank will depend on the type size and water pressure feeding the softener Dependent...

Page 3: ...short as possible Ensure that both the drain and overflow are not subject to excessive temperatures freezing or over 120 F If you are siting the softener in a cupboard ensure that the base of the cupboard is adequately supported If the softener is being installed in a loft it is recommended that you house the softener within a well insulated 25 gallon tank The overflow on the tank should be below ...

Page 4: ...an run up hill to a maximum of 3 feet with a minimum pressure of 40psi Softened water will have no adverse effect on a septic tank Overflow Connection The overflow connection is the white hose spigot on the rear or side of the cabinet No clip is required for this connection The overflow must be run downhill through an outside wall without kinks or restriction It is recommend the overflow hose be v...

Page 5: ... at this stage to allow you to confirm that the unit has no leaks from the installed valves and the waste runs free This regeneration will also assist in clearing any potential air locks that may be present within the system The regeneration will also reset any internal meter or timer devices that dictate the frequency of the regeneration cycle It is important that you have your softener regularly...

Page 6: ...nual regeneration Press and hold the controller 1 for three seconds This will initiate an immediate regeneration The display will show a cascading symbol as it cycles to backwash The unit will proceed through a complete regeneration Delayed regeneration If you need to set up a delayed regeneration follow these steps Press and release the regeneration controller 1 The unit will regenerate at the ne...

Reviews: