Desuperheater Kit Information
For SC Compressor Units:
The field installed ETI Desuperheater Kit Model DSH-1872 equips the SC Series
Compressor Unit
with supplemental water heating capability during (1) heating and
cooling mode operation or (2) cooling mode operation for the ETI Heating and
Cooling System.
Use of the desuperheater to heat water during the heating season will increase the heating
load on the space heating equipment by 2,000 BTUH for each adult and teenager
occupant.
For CC Compressor Units:
The field installed ETI Desuperheater Kit Model DSH-1872 equips the CC Series
Compressor Unit
with supplemental water heating capability during cooling mode
operation.
For SC and CC Compressor Units:
Typical water piping installed with an existing or new standard storage water heater is
illustrated in Figure 1.
Water piping for the desuperheater installed with an ETI Model GSTE Storage Water
Heater is illustrated in Figure 2. The GSTE Series Storage Water Heater is available in 60,
80 and 119 gallon capacities with water piping connections built into the top of the storage
water heater specifically for use with the desuperheater. All GSTE Series models are
equipped with a 4.5 kW electric heater and provide the following hot water recovery rates in
gallons per hour, for a range of water temperature increases, in degrees Fahrenheit.
ΔT
30
40
50
60
70
80
90
GPH
62
46
37
31
26
23
21
*
ΔT in ºF; GPH in U.S. Gallons per hour.
Summary of Contents for DSH-1872
Page 5: ...DSH KIT 04 13 Page 5 Figure 2 Desuperheater installed with GSTE Storage Water Heater...
Page 6: ...DSH KIT 04 13 Page 6 Figure 3a SC Field Wiring for Desuperheater Kit...
Page 7: ...DSH KIT 04 13 Page 7 Figure 3b CC Compressor Unit Field Wiring...
Page 11: ...DSH KIT 04 13 Page 11 Figure 4 SC Cabinet Dimensions and Connections...
Page 12: ...DSH KIT 04 13 Page 12 Figure 5 CC Cabinet Dimensions and Connections...
Page 13: ...DSH KIT 04 13 Page 13 Figure 6 SC Internal Flow Schematic with Desuperheater...
Page 14: ...DSH KIT 04 13 Page 14 Figure 7 SC Piping with Desuperheater...
Page 15: ...DSH KIT 04 13 Page 15 Figure 8 CC Internal Flow Schematic with Desuperheater...
Page 16: ...DSH KIT 04 13 Page 16 Figure 9 CC Piping with Desuperheater...