background image

 

ACM-410D-IM (11/12) 

 

Page 2 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disclaimer 

The EarthLinked

®

 Auxiliary Cooling Module is sold as a system component part and must be 

properly sized and matched to the system compressor unit to provide the intended performance 
and safe operation of the system.  This component must be installed by a trained technician who 
has successfully completed the ETI training class and passed the final examination. Installation 
must be made in accordance with the instructions set forth within this manual. 

Failure to provide installation by an authorized, trained installer in a manner consistent with this 
manual will void the limited warranty coverage for the EarthLinked

® 

system.

 

Earthlinked

 

Technologies shall not be liable for any defect, unsatisfactory performance, damage or 

loss, whether direct or consequential, relative to the design, manufacture, construction, application 
or installation of other components in the EarthLinked

® 

system. 

 

 
 
 
 
 
 
 
 
 

Earthlinked Technologies, Inc. 

4151 South Pipkin Road 

Lakeland, Florida 33811 

tel. 863-701-

0096 ● fax 863-701-7796 

info@earthlinked

.com ● 

www.earthlinked.com

 

Summary of Contents for ACM-024C

Page 1: ...12 Earthlinked Technologies Inc EarthLinked Auxiliary Cooling Module Models ACM 024C thru ACM 072C For R 410A Installation Manual CONTENTS PAGE Pre Installation 3 Installation 5 Placement 5 Refrigeran...

Page 2: ...e with the instructions set forth within this manual Failure to provide installation by an authorized trained installer in a manner consistent with this manual will void the limited warranty coverage...

Page 3: ...of the system The table below lists the properly matched EarthLinked Auxiliary Cooling Module models with EarthLinked compressor unit models Application of the Auxiliary Cooling Module ACM to R 410A s...

Page 4: ...t Dimensions Full Load Amps Rated HP Nominal RPM Width inches Depth inches Height inches ACM 024C 230 1 60 207 253 0 9 5 0 0 7 1 10 1010 24 25 24 25 24 50 ACM 036C 230 1 60 207 253 0 9 5 0 0 7 1 10 10...

Page 5: ...1 Auxiliary Cooling Module Placement in EarthLinked System Location Requirements for the Auxiliary Cooling Module 1 Within 40 Feet of the earth loop line set Minimize refrigerant line lengths 2 Highe...

Page 6: ...ate the Auxiliary Cooling Module per local climate and code requirements to provide clearance above estimated snowfall level and ensure adequate water drainage of Auxiliary Cooling Module Use snow sta...

Page 7: ...at the factory They should be un brazed at the time that tubing is to be connected to the Auxiliary Cooling Module After locating the Auxiliary Cooling Module as noted earlier a trench 3 to 4 Feet de...

Page 8: ...12 Page 8 Figure 3 Auxiliary Cooling Module Refrigerant Piping A top view of typical Auxiliary Cooling Module and line set vapor line connections are illustrated in Figure 4 Figure 4 Top View of Line...

Page 9: ...refrigerant piping connections This process eliminates oxidation products from inside joint surfaces TECHNIQUE Trickle nitrogen gas at 1 2 psi pressure through the joint area being brazed to displace...

Page 10: ...ropriate breakers remove the front and top panels of the compressor unit cabinet 2 Reference Figure 5 for compressor unit electrical box Remove available hole covers from the front of the electrical b...

Page 11: ...older and tighten the other terminal screw of the terminal block onto the stripped end of the gray wire 9 Run high voltage wiring from the two pole terminal strip in the electrical box out of the grom...

Page 12: ...ng Module Field Wiring 12 Check all wiring and electrical connections to ensure proper routing and good contact before restoring electric power evacuating and recharging system in accordance with the...