SPECIFICATIONS -

 

Model BV4000C-2 

 

PAGE 22 

Maximum log length 

18" / 457 mm

 

 

Flue size 

6" / 152 mm

 

 

Width w/standard surround  42" / 107cm

 

 

Width at fireplace opening  22.5" / 572 mm

 

 

Width at rear of firebox 

22.5" / 572 mm

 

 

Depth into Fireplace 

16" / 406 mm

 

 

Depth (overall) 

25" / 635 mm

 

 

Height 

21" / 533 mm

 

 

Height w/standard surround 32" / 813 mm

 

 

Back of Stove to

 

Center of Flue 

 5 1/2" / 140mm

 

 

Approx. burn time 

8 - 10 hours

 

 

Fuel capacity 

70 lbs. / 32 kg (approx.)

 

 

Firebox size (cubic feet) 

2.4 c.f. (732 cubic mm)

 

 

Maximum Burn Rate 

56,800 BTU

 

 

EPA BTU Range  

6,500 to 40,900 BTU

 

 

EPA Efficiency 

72%

 

 

Emissions Rate (grams/hour)  1.9 gph

 

 

Weight with brick 

390 lbs. /177 kg (approx.)

 

 

Air Control 

Manual

 

 

Blower Assembly 

250 cfm

 

(2 blowers, 125cfm each)

 

W/ speed control Rheostat 

75 – 110 volt 

 

Note: Dimensions shown are approximations only 
(+/- ¼”). 

Front View 

 

 
 

Top View 

 

 

 
 

Side View

 

 

 

 

 

f i r e - p a r t s . c o m

Summary of Contents for BV4000C-2

Page 1: ...RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE EPA CERTIFIED CATALYTIC WOOD BURNING FIREPLACE INSERT THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER READ ENTIRE MANUAL THOROUGHLY BEFORE INS...

Page 2: ...tor glows you are overfiring Overfiring this ap pliance could cause a house fire Overfiring is a condition where the appliance is operated at temperatures above its design capabilities see Overfiring...

Page 3: ...TIONS ON THE PURCHASE OF YOUR NEW WOOD BURNING FIREPLACE INSERT MANUFACTURED BY LENNOX HEARTH PROD UCTS When you purchased your new insert you joined the ranks of thousands of concerned individuals wh...

Page 4: ...e partment for requirements in your area IMPORTANT THIS APPLIANCE IS NOT APPROVED FOR INSTALLATION INTO A MANUFACTURED MO BILE HOME IN CANADA OR IN THE USA FLOOR PROTECTION This appliance requires a h...

Page 5: ...FOR COMBUSTION In well insulated and weather tight homes it may be diffi cult to establish a good draft up your chimney The poor draft is caused by a shortage of air in the house To pro vide the neede...

Page 6: ...IFE Factory Built Fireplace Installation MASONRY FIREPLACES Note Measure fireplace size to make certain the insert will fit before considering the installation This appliance is approved for installat...

Page 7: ...ue size should be no more than 3 three times the cross sec tional area of the size of the fireplace insert flue collar In this case that would be no larger than a 10 inch 254 mm diameter stack area ap...

Page 8: ...Note Measure fireplace size to make certain the in sert will fit before considering the installation Minimum size required for fireplace firebox recessed area into fireplace Height 21 533 mm Width 22...

Page 9: ...mmable adhesive i e RTV High Temperature Silicone rated 570 F 4 Use a large piece of cardboard or other protective material and place it in front of the fireplace to protect floor or carpet during ins...

Page 10: ...r attach the positive flue connection to the insert See Note SURROUND ASSEMBLY PURCHASED SEPARATELY NOTE Do not face seal over chimney cooling air system on superior brand or any brand fireplace which...

Page 11: ...open posi tion If this is not possible it will be necessary to remove the damper Installation into a masonry fireplace re quires as a minimum of a flue extension past the header This can be accomplish...

Page 12: ...ill affect the control setting The same con trol settings in a variety of installations will produce different results You will need to try different settings so you can learn how much heat to expect...

Page 13: ...handle to the 6 00 position See illustration above GLASS The Glass is a super heat resistant ceramic that with stands continuous temperatures up to 1390 F This tem perature is well beyond the tempera...

Page 14: ...ring the refueling we recommend that the stove be refired for about 10 minutes with the bypass open to ensure a good draw is established and that the catalyst reaches 600 F The refiring will ensure su...

Page 15: ...urned off by rotating the rheostat dial counterclockwise until it clicks CAUTION BURNING THE INSERT AT A HIGH BURN RATE FOR EXTENDED PERIODS WITHOUT RUN NING THE BLOWERS CAN CAUSE EXCESSIVE TEMPERATUR...

Page 16: ...can produce conditions which will deteriorate metal or damage the cata lyst Green or uncured wood does not work well as fuel and can cause increased creosote buildups and plugging of the catalytic co...

Page 17: ...DUMP GASKET A 3 4 spun fiberglass gasket provides the seal around the fuel door and a flat spun fiberglass rope gasket 1 8 x 1 provides the seal around the glass A cerawool pad 4 1 4 x 4 1 4 x 1 2 pr...

Page 18: ...age 19 for instructions on removing catalytic combus tor IMPORTANT MAKE SURE THE BYPASS DAMPER IS IN THE OPEN POSITION PRIOR TO CHIMNEY CLEANING In the event of a chimney fire Make sure the fuel door...

Page 19: ...ed water for 30 minutes Then rinse by soak ing in hot distilled water After 15 minutes remove the combustor from the rinse water and gently shake out excess water It is unlikely that you will notice a...

Page 20: ...t seal on the fuel door ash dump cover or glass is leaking air Repair or replace it if necessary 4 There is an obstruction in the chimney 5 The stove was not up to normal operating tempera ture before...

Page 21: ...ecessary for achieving the required flow of combustion air to the fire chamber and for safely removing unwanted combustion byproducts from the appliance If the venting system s design does not promote...

Page 22: ...mm Back of Stove to Center of Flue 5 1 2 140mm Approx burn time 8 10 hours Fuel capacity 70 lbs 32 kg approx Firebox size cubic feet 2 4 c f 732 cubic mm Maximum Burn Rate 56 800 BTU EPA BTU Range 6...

Page 23: ...damper bypass BV100 Probe Combustor Temperature 11485 Housing Combustor Room Air Blower Parts LB 101495 Blower Assembly includes 2 blowers w propellers mounting bracket and terminal block 11565 Disc L...

Page 24: ...99 Paint Kit Metallic Black 12 oz Spray 6309 Firebox Parts 11709 Cover Ash Dump w Gasket 4 1 4 x 4 1 4 x 1 2 26M73 Damper Kit Includes damper linkage and rod FB10 Firebrick 4 1 2 x 1 1 4 FB11 Firebric...

Page 25: ...G 26M73 CATALYTIC DAMPER COMPONENTS PRIMARY AIR CONTROL DRAFT MODULE CATALOG 26M68 HANDLE ASSEMBLY P N LB 102214 DOOR ASSEMBLY Cat No 14M72 Gold and Cat No H0533 Black Includes Handle Assembly Not Sho...

Page 26: ...he blower system can be easily transferred to the other side of the insert along with the power cord by installing this cord changeover kit This kit consists of a reversed right and left panels with c...

Page 27: ...SAFETY LISTING LABEL Model BV4000C 2 PAGE 27 fire parts com...

Page 28: ...EPA LABEL Model BV4000C 2 PAGE 28 fire parts com...

Page 29: ...CORDS PAGE 29 Dealer s Name Dealer s Address City State Zip Code Serial Number Date of Purchase Date Installed Notes SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Description fir...

Page 30: ...1110 West Taft Avenue Orange CA 92865 fire parts com...

Reviews: