Master Board
Slave Board
Gate opening direction, motor brake
and close timer.
Use 20GA stranded wire
Use 20GA stranded wire for
Master/Slave communication
NOTE
: Correct polarity between
Master & Slave is necesary
When using these connections
Master Control Options
NOTE:
If the Master and Slave Operators are not communicating
properly, verify if they are on the same phase by switching the phase
jumper on either the master or the Slave Unit.
Master and Slave Operation
____________________
Set dip switch #1
(ON) for the Master
Set dip switch #1
(OFF) for the Slave
Use the feature selector on the master operator to choose available features by designating
the various switches (2 through 4).