EAGLE-II Swing Gate Operator
Two Way Adjustable Reverse Sensor / ERD
____________________
An experienced installer should make all adjustments to the sensor
CAUTION!
!
Eagle Access Control Systems, Inc. / (800) 708-8848 / www.eagleoperators.com
(10)
The level of sensitivity has
to do with the weight of the
gate and the conditions of
the installation.
The Eagle Diamond Control Board
has two separate pots for adjusting
sensitivity. One is for opening the
gate, and the other is for closing the
gate.
There is an LED "OVERLOAD" warning
that will light up when the gate is
heavier than normal for the operator.
During this warning, the operator will
not function properly.
IMPORTANT
Too Sensitive = if the gates stops or reverses by itself
Not Sensitive enough = if the gate strikes an object and does not stop or reverse
When Adjusting Sensors Remember...
Too Sensitive = if the gates stops or reverses by itself
Not Sensitive enough = if the gate strikes an object and does not stop or reverse
Summary of Contents for Power II
Page 1: ...I NSTALLATION M ANUAL ...